AMT58x-CB CANopen®
36
6.11 Node guarding protocol
At system boot the “Node guarding protocol” is disabled; this protocol
is enabled automatically as soon as the master device sends a RTR
message (Remote Transmission Request) the first time.
100C-00 Guard time
:
interval between two RTR messages.
Node life time:
maximum time available for the encoder to
receive a RTR message.
Node life time =
100C-00 Guard time
100D-00 Life time factor
.
“Node guarding” is enabled if Node life time
0.
If the slave does not receive a RTR message before the Node life
time has expired, it warns activating a “Life Guarding Event”.
Furthermore the red LED starts flashing so indicating the Node
guarding error, objects
1001-00 Error register
and
1003 Pre-defined
error field
are updated and an error message is sent.
To reset the error send a Reset node command.
time
Master Slave
RTR
request
NodeGuard.
response
RTR
request
Node
life time
Node guarding
event
Life guarding
event
Guard
time
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]