AMT58x-CB CANopen®
33
This object sets a custom number of distinguishable steps per
revolution.
Enabled if bit 2
Scaling function
in the object
6000-00 Operating
parameters
= “1”.
To avoid counting errors, check that
6501-00 Hardware counts per
revolution
= integer value.
6001-00 Counts per revolution
Allowed values are equal to or lower than
6501-00 Hardware counts
per revolution
( (see encoder label).
WARNING
Every time you change the value in this object then you are required
to set a new preset value (see object
6003-00 Preset value
) and
finally save the new parameters (see object
1010-01 Store
parameters
).
6002-00 Total resolution
[Unsigned32, rw]
This object sets a custom number of distinguishable steps over the
total measuring range.
Enabled if bit 2
Scaling function
in the object
6000-00 Operating
parameters
= ”1”.
Allowed values are equal to or lower than
Total hardware
resolution
(
6501-00 Hardware counts per revolution
*
6502-00
Hardware number of turns
, see encoder label).
WARNING
Every time you change the value in this object then you are required
to set a new preset value (see object
6003-00 Preset value
) and
finally save the new parameters (see object
1010-01 Store
parameters
).
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]