AMT58x-CB CANopen®
8
4.2 Ground connection
Minimize noise by connecting the shield and/or the connector
housing and/or the frame to ground. Make sure that ground is not
affected by noise. The connection point to ground can be situated
both on the device side and on user’s side.
The best solution to minimize the interference must be carried out by
the user. You are advised to provide the ground connection as close
as possible to the encoder. We suggest using the ground point
provided in the cap (see Figure, use 1 TCEI M3 x 6 cylindrical head
screw with 2 tooth lock washers).
4.3 Connection cap
The connection cap is fitted with two PG9 cable glands for bus-IN,
bus-OUT and supply voltage connections. The bus cables can be
connected directly to the terminal connectors in front of each cable
gland. It is recommended to use CANbus certificated cables.
Core diameter should not exceed Ø 1,5 mm (0.06 inches).
Clamp Description
-
0 VDC
Supply voltage
+
+10VDC +30VDC
Supply voltage
G
CAN GND
1
L CAN
Low
H CAN
High
PG
CAN Shield
2
1
CAN GND is the 0V reference of CAN signals, it is not connected to
0VDC supply voltage.
2
Connect cable shield to cable gland.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]