AMT58x-CB CANopen®
31
3001-00 Node-ID
[Unsigned8, rw]
This object defines the node identifier of the device.
The node number is set through the object
3001-00 Node-ID
only if
all bits of DIP B are set to ”OFF”. If one bit at least of DIP B is set to
“ON” the node number is set through DIP B. For any further
information refer to “4.9 Node number: DIP B”
To change the Node-ID value you have to:
set the object
3001-00 Node-ID
;
send a Reset node command;
save the parameter.
Default = 01h
Master
Encoder
COB-ID
Cmd Index Sub Data
byte
600+ID 2F 01
30
00
new
Node-ID
Encoder
Master (confirmation)
COB-ID
Cmd Index Sub Data
byte
580+ID 60 01
30
00
00
Master
Encoder (Reset node)
COB-ID
Cmd Slave
ID
000 81
old
ID
Encoder
Master (Boot-up with new Node-ID)
COB-ID
Cmd
700+ID 00
NOTE
To save the new Node-ID value execute the store parameters
function (see object
1010-01 Store parameters
).
When the power is turned off, parameters not saved will be lost.
3005-00 Velocity format
[Unsigned8, rw]
This attribute defines the engineering units for the velocity value.
00h = steps/s:
number of steps per second (default);
01h = rpm: revolutions per minute.
3006-00 Velocity value
[Unsigned32, ro]
This attribute shows the current speed detected by the position
sensor and calculated every 100 ms.
Value is transmitted according to the settings in the object
1803
PDO4 parameters
.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]