AMT58x-CB CANopen®
27
Master
Encoder
COB-ID
Cmd Index Sub Data
byte
600+ID 2F 00
30 00 see
table
Encoder
Master (confirmation)
COB-ID
Cmd Index Sub Data
byte
580+ID 60 00
30 00
00
Master
Encoder (Reset node)
COB-ID
Cmd Slave
ID
000 81 ID
Set the master device to the new baud rate:
Encoder
Master (Boot-up with new baud rate)
COB-ID
Cmd
700+ID 00
NOTE
To save the new Baud rate value execute the store parameters
function (see object
1010-01 Store parameters
).
When the power is turned off, parameters not saved are lost.
3001-00 Node-ID
[Unsigned8, rw]
This object defines the node identifier of the device.
The node number is set through the object
3001-00 Node-ID
only if
all bits of DIP B are set to ”OFF”. If one bit at least of DIP B is set to
“ON” the node number is set through DIP B. For any further
information refer to section “4.9 Node number: DIP B”.
To change the Node-ID value you have to:
set the object
3001-00 Node-ID
;
send a Reset node command;
save the parameter.
Default = 01h
Master
Encoder
COB-ID
Cmd Index Sub Data
byte
600+ID 2F 01
30
00
new
Node-ID
Encoder
Master (confirmation)
COB-ID
Cmd Index Sub Data
byte
580+ID 60 01
30
00
00
Master
Encoder (Reset node)
COB-ID
Cmd Slave
ID
000 81 Old
ID