AMT58x-CB CANopen®
24
1008-00 Name of device manufacturer
[String, ro]
It shows the name of the device manufacturer.
Default = “Datalogic Automation Srl”
1009-00 Hardware version
[String, ro]
It shows the hardware version of the device.
100A-00 Software version
[String, ro]
It shows the software version of the device.
100C-00 Guard time
[Unsigned16, rw]
It contains the Guard time expressed in msec (milliseconds).
Object
100C-00 Guard time
is used in the “Node guarding protocol”
controlled by the master. For more details see section “6.11 Node
guarding protocol”.
Default = 0000h
100D-00 Life time factor
[Unsigned8, rw]
Object
100D-00 Life time factor
is used in the “Node guarding
protocol” controlled by the master. For more details see section “6.11
Node guarding protocol”.
Default = 00h