AMT58x-CB CANopen®
13
5. Quick reference
Using the default settings provided by the manufacturer, you can
switch on the device and read immediately its position.
Follow the instructions below to:
read the device resolution;
set the
Operational
mode;
read the current position (cyclic mode and/or sync mode).
Default Baud rate and Node-ID are:
Baud rate = 500 Kbit/s
Node-ID = 1
Read resolution per revolution
6501-00 Hardware counts per
revolution
Master
Encoder
COB-ID Cmd Index Sub
Process
data
601
40 01 65 00 - - - -
Encoder
Master
COB-ID Cmd Index Sub
Process
data
581
43 01 65 01 A0 A1 A2 A3
steps/rev. = ( (A3<<24) | (A2<<16) | (A1<<8) | A0 )
Read number of revolutions
6502-00 Hardware number of turns
Master
Encoder
COB-ID Cmd Index Sub
Process
data
601
40 02 65 00 - - - -
Encoder
Master
COB-ID Cmd Index Sub
Process
data
581
43 02 65 01 B0 B1 B2 B3
N. rev. =( (B3<<24) | (B2<<16) | (B1<<8) | B0 )
Set cyclic time
6200-00 Cyclic time
(100 ms = 64h)
Master
Encoder
COB-ID Cmd
Index Sub
Process data
600+ID 2B 00 62 00 64 00 - -
Encoder
Master
COB-ID Cmd
Index Sub
Process data
580+ID 60 00 62 00 00 00 - -
Set
Operational
mode
Master
Encoder
COB-ID Cmd
Node
000 01 01
Read the position every 100 ms
Encoder
Master
COB-ID
Byte 0
Byte 1
Byte 2
Byte 3
181 Low … … High
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]