Operation
Operating Procedures
3-4
DataComm V.34 PL Modem
060R115-000
Installation and Operation
Issue 1
Configuration
The DataComm V.34 PL leased-line only modem allows you to select a configuration profile. As
soon as it is powered up, it performs a display test then displays “
gdc”
momentarily, then
continuously enters the leased line handshake mode.
To configure the modem you must first place the modem in the idle mode. (the modem is in the idle
mode if the decimal point at the far right of the display is flashing and the front panel
MR
and
GD
LEDS are OFF. Press the front panel
RST
button to enter the idle mode. This may take four to five
seconds after the button is pressed.
To scroll though the profile configurations, press
ADV
. Profiles include
FAC0
through
FAC3
and
USr0
through
USr3
.
Front Panel Configuration Procedure Summary
Before attempting to configure the DataComm V.34 PL you must identify whether you require 4
Wire (4W) or 2 Wire (2W) Private Line operation and whether you want the answer or originate
function. Then chose the appropriate factory fixed default followed by the appropriate options. The
Main Profile Menu is shown below:
To enter configuration mode press
SEL
, then press
ADV
(within two
seconds). The modem briefly displays the last profile saved or selected
from the front panel. The example illustrates the display for FACtory
(fixed) profile 0.
Once in configuration mode, there is a slight delay between the switch
entry and the next LED update. Do not press the switch until the LED
display updates, you may inadvertently select the next entry.
-
FAC0 (4W Orig.)
Recalls factory default 0 profile
(when saved, resets USr0 to FAC0 defaults)
FAC1 (4W Ans.)
Recalls factory default 1 profile
(when saved, resets USr1 to FAC1 defaults)
FAC2 (2W Orig.)
Recalls factory default 2 profile
(when saved, resets USr2 to FAC2 defaults)
FAC3 (2W Ans.)
Recalls factory default 3 profile
(when saved, resets USr3 to FAC3 defaults)
USr0
4-wire, Originate
USr1
4-wire, Answer
USr2
2-wire, Originate
USr3
2-wire, Answer
rEL
Displays firmware version
Note
You must start with a factory fixed default of
FAC0
,
FAC1
,
FAC2
or
FAC3
for first time
configuration setup. For subsequent configuration changes you would choose USr1 through
USr3 depending on which USr profile the options were stored in.
Содержание V.34 PL
Страница 1: ...DataComm V 34 PL Modem Installation and Operation 060R115 000 Issue 1 ...
Страница 2: ......
Страница 3: ...060R115 000 Issue 1 DataComm V 34 PL Modem Installation and Operation ...
Страница 10: ......
Страница 16: ...Introduction Equipment List 1 4 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 36: ...Operation Operating Procedures 3 12 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 46: ...Tests End to End Self Test 4 10 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 50: ...Technical Specifications A 4 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 55: ......
Страница 56: ......