V.34 PL Quick Reference
060R115-000
Issue 1
Mode
FAC0
FAC1
FAC2
FAC3
4W Originate
4W Answer
2W Originate
2W Answer
Mode of Operation
OP
A - Asynchronous
S - Synchronous (FAC0-FAC3)
Word Length
Ln
9 - 9 bits
10 - 10 bits (FAC0-FAC3)
Timing
tI
In - Internal (FAC0-FAC3)
Et - External
rC - Receive
Data Rate
rt
24 - 2400 bps
48 - 4800 bps
96 - 9600 bps (FAC0-FAC3)
Carrier
CA
S - Simulated Control Carrier V.13 (FAC0-
FAC3)
r - Real/Constant
RTS/CTS Delay
dE
0-0ms
15-15 ms (FAC0-FAC3)
Transmit Levels
tL
0 dBm to -15 dBm
-9 dBm (FAC0-FAC3)
* Terminal Test Control
tC
d - Disabled
E - Enabled (FAC0-FAC3)
Front Panel Test Duration
FP
I - Infinite
10 - 10 minutes (FAC0-FAC3)
Parity
Pr
En - Even
SP - Space
Od - Odd
Ar - Mark
At - Auto (FAC0-FAC3)
Notes: Defaults shown in Bold for FAC0 through FAC3
* If EIA pins 18 and 21 are not used, this option must be disabled (d) to prevent the modem from randomly
entering the Test Mode.
Содержание V.34 PL
Страница 1: ...DataComm V 34 PL Modem Installation and Operation 060R115 000 Issue 1 ...
Страница 2: ......
Страница 3: ...060R115 000 Issue 1 DataComm V 34 PL Modem Installation and Operation ...
Страница 10: ......
Страница 16: ...Introduction Equipment List 1 4 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 36: ...Operation Operating Procedures 3 12 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 46: ...Tests End to End Self Test 4 10 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 50: ...Technical Specifications A 4 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 55: ......
Страница 56: ......