060R115-000
DataComm V.34 PL Modem
4-1
Issue 1
Installation and Operation
Chapter 4:
Tests
Overview
This chapter describes tests that you can perform to isolate a trouble condition. The tests can isolate
a problem to the data connection, modem operation, or the DTE interface level. Refer to
Figure 4-1
for a sequence of tests for fault isolation.
Figure 4-1
Fault Isolation Sequence
Note
a.
On-line tests, which involve data transmitted from one modem to another, can be performed with
the modems operating in synchronous mode.
b.
Once a modem is in Slave RDL, it will ignore all requests other than AL.
c.
If an MRDL request does not get a response from the Slave modem at 2400 bps, the Master will
drop the line.
PASS
OR
FAIL
?
PASS
FAIL
PASS
OR
FAIL
?
PASS
FAIL
PASS
OR
FAIL
?
PASS
FAIL
PASS
OR
FAIL
?
PASS
FAIL
PASS
OR
FAIL
?
PASS
FAIL
PERFORM
ANALOG LOOPBACK
WITH SELF-TEST
REMOTE MODEM
PROBLEM
START
PERFORM
ANALOG LOOPBACK
COMMUNICATION
LINE PROBLEM
LOCAL MODEM
PROBLEM
LOCAL TERMINAL OR
LOCAL TERMINAL-MODEM
CONNECTION PROBLEM
PERFORM REMOTE
DIGITAL LOOPBACK WITH
SELF-TEST AT REMOTE MODEM
PERFORM LOCAL
DIGITAL LOOPBACK
WITH SELF-TEST
PERFORM REMOTE
DIGITAL LOOPBACK
WITH SELF-TEST
REMOTE TERMINAL OR
REMOTE TERMINAL-MODEM
CONNECTION PROBLEM
COMMUNICATION
LINE PROBLEM
Содержание V.34 PL
Страница 1: ...DataComm V 34 PL Modem Installation and Operation 060R115 000 Issue 1 ...
Страница 2: ......
Страница 3: ...060R115 000 Issue 1 DataComm V 34 PL Modem Installation and Operation ...
Страница 10: ......
Страница 16: ...Introduction Equipment List 1 4 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 36: ...Operation Operating Procedures 3 12 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 46: ...Tests End to End Self Test 4 10 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 50: ...Technical Specifications A 4 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 55: ......
Страница 56: ......