Technical Specifications
A-2
DataComm V.34 PL Modem
060R115-000
Installation and Operation
Issue 1
Receive Carrier
ITU-T V.34
As specified by ITU-T
Note:
ITU-T V.34 being echo canceling protocols, use signal quality as criteria for maintaining connec-
tion. They also provide for self-training detection to force disconnect.
Receive Level
Two-wire Private Line
-6 to -33 dBm
Four-wire Private Line
0 to -26 dBm
Hysteresis
2 dBm minimum
DTE Interface
Standard
EIA/TIA-232-E (ITU-T V.24/V.28/ISO 2110)
Optional
EIA/TIA-530-A (ITU-T V.10/V.11/V.24/ISO 2110
Amendment 1)
V.35 (ITU-T V.24/V.28/V.35/ISO 2593)
V.36 (requires a special optional cable)
Line Requirements
Private Line
Two-wire or four-wire
Line Connection
Private Line
8-position modular jack (US RJ45)
Line Equalization
Automatic Adaptive
Connection Options
One second Line Break Holdover in four-wire private
line mode only.
Power Consumption
7 card-edge watts dc maximum
DC Voltage (Typical)
+5V
+5V ±5% at 1A
+12V
+12V ±5% at 0.2A
-12V
-12V ±5% at 0.2A
Dimensions (Printed circuit board)
Height
22.2 mm (7/8 in)
Width
248 mm (9 3/4 in)
Depth
273 mm (10 3/4 in)
Item
Specification
Содержание V.34 PL
Страница 1: ...DataComm V 34 PL Modem Installation and Operation 060R115 000 Issue 1 ...
Страница 2: ......
Страница 3: ...060R115 000 Issue 1 DataComm V 34 PL Modem Installation and Operation ...
Страница 10: ......
Страница 16: ...Introduction Equipment List 1 4 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 36: ...Operation Operating Procedures 3 12 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 46: ...Tests End to End Self Test 4 10 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 50: ...Technical Specifications A 4 DataComm V 34 PL Modem 060R115 000 Installation and Operation Issue 1 ...
Страница 55: ......
Страница 56: ......