Pag
e
40
(1)
The error code can be exited in the following ways:
OPERATOR
CONFIRMATION
The machine exits from the error code display when the operator presses any key.
OPERATOR ACTION
The machine exits from the error code display when the operator performs an action linked to said
error code (for example,
ERR 016
brings the Distance sensor back to the rest position).
ONCE
The machines displays once the error code and its brief description, then it returns to the previous
status.
PERMANENT
The machine permanently displays this error code until its turn-off, therefore the error code cannot be
exited.
19.1 Acoustic signals
The machine emits different acoustic signals based on its status. The acoustic signals are listed in table T19.2.
Table T19.2: Acoustic signals
Signals
Meaning
Notes
Very brief beep
Manual entry of wheel geometric data.
Short beep
Selecting a program or a function.
Long beep
Acquisition.
Acquisition of a value
Acquisition of the wheel dimensions in the STD,
ALU1, ALU2, ALU3, ALU4, ALU5 Program Types.
Long beep +
1 Short beep
Acquisition of internal plane in ALS1 or ALS2 Program
Types.
Long beep +
2 Short beep
Acquisition of external plane in ALS1 or ALS2 Program
Types.
Double beep
Warning.
A particular condition has occurred that requires the
operator’s attention.
Triple beep
Function not available or Error.
The requested function is not available or an error
condition has occurred.
Short Beep + Long beep
Storing one or more values in the permanent
memory (eeprom) of the circuit board.
One or more values have been stored in the
permanent memory of the circuit board (for example,
at completion of calibration phases).
Intermittent beep
Adjustment.
Signal used in some service programs to simplify the
adjustment of sensors.
The acoustic signal is also heard for about two seconds at machine start-up allowing the operator to check the operation of the
alarm (buzzer).
20. FIRE PREVENTION MEANS TO USE
Dry materials
Flammable liquids
Electrical equipment
Hydraulic
YES
NO
NO
Foam
YES
YES
NO
Powder
YES*
YES
YES
CO
2
YES*
YES
YES
YES*: Can be used in the absence of more appropriate means or for small fires.
The information in the table above is general and can be used as a rough guide. The responsibility for the use
of each type of extinguisher must be obtained from the manufacturer.