18.8 Select balancing weights material Fe/Zn or Pb
The selection of the material type slightly changes the balancing results because the weights in Iron/Zinc are lighter than those in
Lead and therefore are larger. The machine takes account of these differences when calculating the imbalance.
Table T18.3: Balancing weights materials
Option
Type of balancing weight material
Notes
Fe
Iron or Zinc
This material has been set by default.
Pb
Lead
In some countries (such as those of the European Community), Lead
weights are prohibited by law.
To modify the BALANCING WEIGHTS MATERIAL, proceed as follows:
Op.
Description
10
and select
Press [2] or [4] from the keyboard
the icon relative to the program to be used.
20
Activate the work program with WEIGHTS in IRON/ZINC by selecting
(by default at start-up) which will turn green.
30
Scroll through the list of available program by pressing [1] or [3] on the
keyboard
.
40
Activate the work program in WEIGHTS IN LEAD by selecting
,
ensure that status icon
is activated.