[1]
On
Control via the network is active
12-33 CIP Revision
Option:
Function:
Read only. Displays the CIP-version of the option software.
[0]
Major version (00 - 99)
[1]
Minor version (00 - 99)
12-34 CIP Product Code
Range:
Function:
1100 (FC
302) 1110
(FC 301)*
[0 – 9999]
Read only. Displays the CIP product code.
12-37 COS Inhibit Timer
Range:
Function:
[0 – 65.535 ms]
Read only Change-Of-State inhibit timer. If the option is configured for COS operation, this inhibit
timer can be configured in the Forward Open telegram to prevent that continuously changing PCD
data generates extensive network traffic. The inhibit time is in milliseconds, 0 = disabled.
12-38 COS Filters
Range:
Function:
[[0 - 9] Filter 0 – 9 (0000 -
FFFFhex)]
Change-Of-State PCD filters. Sets up a filter mask for each word of process data when operating in
COS-mode. Single bits in the PCD’s can be filtered in/out.
6.2.5 Other EtherNet Services
12-80 FTP Server
Option:
Function:
[0] *
Disable
Disables the built-in FTP server.
[1]
Enable
Enables the built-in FTP server.
12-81 HTTP Server
Option:
Function:
[0] *
Disable
Disables the build-in HTTP (web) server.
[1]
Enable
Enables the build-in HTTP (web) server.
12-82 SMTP Service
Option:
Function:
[0] *
Disable
Disables the SMTP (e-mail) service on the option.
[1]
Enable
Enables the SMTP (e-mail) service on the option.
12-89 Transparent Socket Channel Port
Range:
Function:
0*
[0 – 9999]
Configures the TCP port-number for the transparent socket channel. This enables FC-telegrams to
be sent transparently on Ethernet via TCP. Default value is 4000, 0 means disabled.
MCA 121 EtherNet/IP
6 Parameters
MG.90.J2.02 - VLT
®
is a registered Danfoss trademark
39
6
Содержание VLT MCA 121 EtherNet/IP
Страница 14: ...4 How to Configure MCA 121 EtherNet IP 14 MG 90 J2 02 VLT is a registered Danfoss trademark 4...
Страница 20: ...5 How to Control MCA 121 EtherNet IP 20 MG 90 J2 02 VLT is a registered Danfoss trademark 5...
Страница 50: ...8 Appendix MCA 121 EtherNet IP 50 MG 90 J2 02 VLT is a registered Danfoss trademark 8...