![Danfoss VLT MCA 121 EtherNet/IP Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/danfoss/vlt-mca-121-ethernet-ip/vlt-mca-121-ethernet-ip_manual_3698712033.webp)
8-14 Configurable Control Word CTW
Option:
Function:
Selection of control word bit 10 if it is active low or active high
[0]
None
[1] *
Profile default
[2]
CTW Valid, active low
8-50 Coasting Select
Option:
Function:
Select control of the coasting function via the terminals (digital input) and/or via the bus.
[0]
Digital input
[1]
Bus
Activates Start command via the serial communication port or fieldbus option.
[2]
Logic AND
Activates Start command via the fieldbus/serial communication port, AND additionally via one of the
digital inputs.
[3] *
Logic OR
Activates Start command via the fieldbus/serial communication port OR via one of the digital inputs.
NB!
This parameter is active only when par.8-01
is set to [0]
Digital and control word
.
MCA 121 EtherNet/IP
6 Parameters
MG.90.J2.02 - VLT
®
is a registered Danfoss trademark
33
6
Содержание VLT MCA 121 EtherNet/IP
Страница 14: ...4 How to Configure MCA 121 EtherNet IP 14 MG 90 J2 02 VLT is a registered Danfoss trademark 4...
Страница 20: ...5 How to Control MCA 121 EtherNet IP 20 MG 90 J2 02 VLT is a registered Danfoss trademark 5...
Страница 50: ...8 Appendix MCA 121 EtherNet IP 50 MG 90 J2 02 VLT is a registered Danfoss trademark 8...