[30]
Brake fault (IGBT)
Output is Logic ‘1’ when the brake IGBT is short-circuited. Use this function to protect the frequency
converter if there is a fault on the brake modules. Use the output/relay to cut out the main voltage
from the frequency converter.
[31]
Relay 123
Relay is activated when Control Word [0] is selected in parameter group 8-**.
[32]
Mechanical brake control
Enables control of an external mechanical brake, see description in the section
Control of Mechanical
Brake
, and par. group 2-2*
[33]
Safe stop activated (FC 302 only)
Indicates that the safe stop on terminal 37 has been activated.
[40]
Out of ref range
[41]
Below reference low
[42]
Above reference high
[45]
Bus Ctrl
Controls output via bus. The state of the output is set in par. E-90 Digital
& Relay Bus Control
. The
output state is retained in the event of bus time-out.
[46]
Bus Ctrl On at timeout
Controls output via bus. The state of the output is set in par. E-90 Digital
& Relay Bus Control
. In
the event of bus time-out the output state is set high (On).
[47]
Bus Ctrl Off at timeout
Controls output via bus. The state of the output is set in par. E-90 Digital
& Relay Bus Control
. In
the event of bus time-out the output state is set low (Off).
[51]
MCO controlled
[55]
Pulse output
[60]
Comparator 0
See par. group 13-1*. If Comparator 0 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
[61]
Comparator 1
See par. group 13-1*. If Comparator 1 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
[62]
Comparator 2
See par. group 13-1*. If Comparator 2 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
[63]
Comparator 3
See par. group 13-1*. If Comparator 3 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
[64]
Comparator 4
See par. group 13-1*. If Comparator 4 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
[65]
Comparator 5
See par. group 13-1*. If Comparator 5 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
[70]
Logic Rule 0
See par. group 13-4*. If Logic Rule 0 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
[71]
Logic Rule 1
See par. group 13-4*. If Logic Rule 1 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
[72]
Logic Rule 2
See par. group 13-4*. If Logic Rule 2 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
[73]
Logic Rule 3
See par. group 13-4*. If Logic Rule 3 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
[74]
Logic Rule 4
See par. group 13-4*. If Logic Rule 4 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
[75]
Logic Rule 5
See par. group 13-4*. If Logic Rule 5 is evaluated as TRUE, the output will go high. Otherwise, it
will be low.
[80]
SL Digital Output A
See par. LC-52 Logic
Controller Action
. The output will go high whenever the Smart Logic Action
[38]
Set dig. out. A high
is executed. The output will go low whenever the Smart Logic Action [32]
Set dig. out. A low is executed.
[81]
SL Digital Output B
See par. LC-52 Logic
Controller Action
. The input will go high whenever the Smart Logic Action [39]
Set dig. out. A high
is executed. The input will go low whenever the Smart Logic Action [33]
Set
dig. out. A low
is executed.
[82]
SL Digital Output C
See par. LC-52 Logic
Controller Action
. The input will go high whenever the Smart Logic Action [40]
Set dig. out. A high
is executed. The input will go low whenever the Smart Logic Action [34]
Set
dig. out. A low
is executed.
5. Parameter Set-up
FC 300 Extended Relay Card Operating In-
structions
16