7.1.3 Mains Supply 3x525–600 V AC
Type designation
P1K1
P1K5
P2K2
P3K0
P3K7
P4K0
P5K5
P7K5
Overload
1)
NO
NO
NO
NO
NO
NO
NO
NO
Typical shaft output [kW]
1.1
1.5
2.2
3.0
3.7
4.0
5.5
7.5
IP20/chassis
A3
A3
A3
A3
A2
A3
A3
A3
IP21/NEMA 1
A3
A3
A3
A3
A2
A3
A3
A3
IP55/NEMA 12
A5
A5
A5
A5
A5
A5
A5
A5
IP66/NEMA 4X
A5
A5
A5
A5
A5
A5
A5
A5
Output current
Continuous (3x525–550 V) [A]
2.6
2.9
4.1
5.2
–
6.4
9.5
11.5
Intermittent (3x525–550 V) [A]
2.9
3.2
4.5
5.7
–
7.0
10.5
12.7
Continuous (3x525–600 V) [A]
2.4
2.7
3.9
4.9
–
6.1
9.0
11.0
Intermittent (3x525–600 V) [A]
2.6
3.0
4.3
5.4
–
6.7
9.9
12.1
Continuous kVA (525 V AC) [kVA]
2.5
2.8
3.9
5.0
–
6.1
9.0
11.0
Continuous kVA (575 V AC) [kVA]
2.4
2.7
3.9
4.9
–
6.1
9.0
11.0
Maximum input current
Continuous (3x525–600 V) [A]
2.4
2.7
4.1
5.2
–
5.8
8.6
10.4
Intermittent (3x525–600 V) [A]
2.7
3.0
4.5
5.7
–
6.4
9.5
11.5
More specifications
Estimated power loss
3)
at rated maximum load [W]
4)
50
65
92
122
–
145
195
261
IP20 maximum cable cross-section
2)
(mains, motor, brake, and load
sharing) [mm
2
/(AWG)]
4, 4, 4 (12, 12, 12)
(minmum 0.2 (24))
IP55, IP66 maximum cable cross-
section
2)
(mains, motor, brake, and
load sharing) [mm
2
/(AWG)]
4, 4, 4 (12, 12, 12)
(minmum 0.2 (24))
Maximum cable cross-section
2)
with
disconnect
6, 4, 4 (10, 12, 12)
Efficiency
5)
0.97
0.97
0.97
0.97
–
0.97
0.97
0.97
Table 7.5 Mains Supply 3x525–600 V AC
Specifications
Design Guide
MG16G202
Danfoss A/S © 08/2015 All rights reserved.
119
7
7
Содержание VLT FC 103
Страница 2: ......
Страница 159: ...Index Design Guide MG16G202 Danfoss A S 08 2015 All rights reserved 157...