Control card, 10 V DC output
Terminal number
50
Output voltage
10.5 V
±
0.5 V
Maximum load
25 mA
6.8 FCM 106 Motor Specifications
Motor output (U, V, W)
Output voltage
0–100% of supply voltage
Output frequency, asynchronous motor
0–200 Hz (VVC
+
), 0–400 Hz (u/f)
Output frequency, PM motor
0–390 Hz (VVC
+
PM)
Switching on output
Unlimited
Ramp times
0.05–3600 s
Thermistor input (at motor connector)
Input conditions
Fault: >2.9 k
Ω
, no fault: <800
Ω
Specifications