Minimum ambient temperature during full-scale operation
-10
°
C (14
°
F)
Minimum ambient temperature at reduced performance
-20
°
C (-4
°
F)
Maximum ambient temperature at reduced performance
50
°
C (122
°
F)
Temperature during storage
-25 to +65
°
C (-13 to +149
°
F)
Temperature during transport
-25 to +70
°
C (-13 to +158
°
F)
Maximum altitude above sea level without derating
1000 m (3280 ft)
Maximum altitude above sea level with derating
3000 m (9842 ft)
Safety standards
EN/IEC 60204-1, EN/IEC 61800-5-1, UL 508C
EMC standards, emission
EN 61000-3-2, EN 61000-3-12, EN 55011, EN 61000-6-4
EMC standards, immunity
EN 61800-3, EN 61000-6-1/2
Energy efficiency class, VLT
®
DriveMotor FCP 106
2)
IE2
Energy efficiency class, VLT
®
DriveMotor FCM 106
IES
1) The stated IP and Type rating only apply when the FCP 106 is mounted on a wall mount plate or a motor with the adapter
plate. Ensure that the gasket between the adapter plate and the motor has a protection rating corresponding to the required
rating for the combined motor and frequency converter. As standalone frequency converter, the enclosure rating is IP00 and
Open type.
2) Determined according to EN50598-2 at:
•
Rated load.
•
90% rated frequency.
•
Switching frequency factory setting.
•
Switching pattern factory setting.
6.6 Cable Specifications
Cable lengths and cross-sections
Maximum motor cable length for wall mount kit, screened/armored
2 m (6.56 ft)
Maximum cross-section to motor, mains for MH1–MH3
4 mm
2
/11 AWG
Maximum cross-section DC terminals on enclosure type MH1–MH3
4 mm
2
/11 AWG
Maximum cross-section to control terminals, rigid wire
2.5 mm
2
/13 AWG
Maximum cross-section to control terminals, flexible cable
2.5 mm
2
/13 AWG
Minimum cross-section to control terminals
0.05 mm
2
/30 AWG
Maximum cross-section to thermistor input (at motor connector)
4 mm
2
/11 AWG
6.7 Control Input/Output and Control Data
Digital inputs
Programmable digital inputs
4
Terminal number
18, 19, 27, 29
Logic
PNP or NPN
Voltage level
0–24 V DC
Voltage level, logic 0 PNP
<5 V DC
Voltage level, logic 1 PNP
>10 V DC
Voltage level, logic 0 NPN
>19 V DC
Voltage level, logic 1 NPN
<14 V DC
Maximum voltage on input
28 V DC
Input resistance, R
i
Approximately 4 k
Ω
Digital input 29 as pulse input
Maximum frequency 32 kHz push-pull-driven and 5 kHz (O.C.)
Analog inputs
Number of analog inputs
2
Terminal number
53, 54
Terminal 53 mode
Parameter 6-19 Terminal 53 mode
: 1=voltage, 0=current
Terminal 54 mode
Parameter 6-29 Terminal 54 mode
: 1=voltage, 0=current
Voltage level
0–10 V
Input resistance, R
i
Approximately 10 k
Ω
Specifications
VLT
®
DriveMotor FCP 106/FCM 106
68
Danfoss A/S © 06/2016 All rights reserved.
MG03M202