![background image](http://html1.mh-extra.com/html/danfoss/vlt-drivemotor-fcp-106/vlt-drivemotor-fcp-106_design-manual_3512520068.webp)
Enclosure
MH3
P5K5
P7K5
Overload
1)
NO
HO
NO
Typical shaft output [kW]
5.5
7.5
Typical shaft output [hp]
7.5
10
Maximum cable cross-section in terminals
2)
(mains, motor)
[mm
2
/AWG]
4/12
4/12
Output current
40
°
C ambient temperature
Continuous
(3x380–440 V) [A]
12
15.5
Intermittent
(3x380–440 V) [A]
13.2
19.2
17.1
Continuous
(3x440–480 V) [A]
11
14
Intermittent
(3x440–480 V) [A]
12.1
13.2
15.4
Maximum input current
Continuous
(3x380–440 V) [A]
11
15
Intermittent
(3x380–440 V) [A]
12
17
17
Continuous
(3x440–480 V) [A]
9.4
13
Intermittent
(3x440–480 V) [A]
10
15
14
Maximum mains fuses
See
chapter 6.9 Fuse and Circuit Breaker Specifications
Estimated power loss [W], best case/typical
3)
143
236
Efficiency [%], best case/typical
4)5)
0.97
0.97
Table 6.12 Mains Supply 3x380–480 V AC Normal and High Overload: MH3 Enclosure
1) NO: Normal overload, 110% for 1 minute. HO: High overload, 160% for 1 minute.
A frequency converter intended for HO requires a corresponding motor rating. For example, Table 6.11 shows that a 1.5 kW motor for HO requires
a P2K2 frequency converter.
2) Maximum cable cross-section is the largest cable cross-section that can be attached to the terminals. Always observe national and local
regulations.
3) Applies to dimensioning of frequency converter cooling. If the switching frequency is higher than the default setting, the power losses may
increase. LCP and typical control card power consumptions are included. For power loss data according to EN 50-598-2, refer to
www.danfoss.com/vltenergyefficiency.
4) Efficiency measured at nominal current. For energy efficiency class, see chapter 6.5 Ambient Conditions. For part load losses, see
www.danfoss.com/vltenergyefficiency.
5) Measured using 4 m screened motor cables at rated load and rated frequency.
Specifications
VLT
®
DriveMotor FCP 106/FCM 106
66
Danfoss A/S © 06/2016 All rights reserved.
MG03M202
6