195NA445.10
1 2 3 4 5 6 7
8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
F C M 1 0 6
T
4 P 5 5 H
S X X
X
B
33 34 35 36 37 38 39
1 2 3 4 5 6 7
8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
F C P 1 0 6
T
4 P 6 6 H
S
X X
X
E
1
1
Illustration 5.1 Type Code String Example
5.2.1 Motor Frame Sizes and Flanges
Flange sizes corresponding to motor frame size and FCM 106 rating are listed in
FCM 106
rating [kW]
Motor
frame size
Mounting version
Flange size, standard (S)
Flange size, alternatives (B)
4 pole
[mm]
[mm]
0.55
80
B5/B35
165
–
B14/B34
100
75/85/115/130
0.75
80
B5/B35
165
–
B14/B34
100
75/85/115/130
1.1
90
B5/B35
165
215
B14/B34
115
85/100/130/165
1.5
90
B5/B35
165
215
B14/B34
115
85/100/130/165
2.2
100
B5/B35
215
–
B14/B34
130
85/100/115
3.0
100
B5/B35
215
–
B14/B34
130
85/100/115
4.0
112
B5/B35
215
–
B14/B34
130
85/100/115
5.5
132
B5/B35
265
–
B14/B34
165
–
7.5
132
B5/B35
265
–
B14/B34
165
–
Table 5.2 Flange Sizes Corresponding to FCM 106 Rating
S: Available as standard shaft.
B: Available as an alternative with standard shaft for frame, requiring no modification.
Type Code and Selection Gui...