6.1.2 Motor Frame Size Corresponding to
FCP 106 Enclosure
PM motor
Asynchronous motor
FCP 106
RPM
Enclosure
Power
[kW (hp)]
1500 3000
3000
1500
71
–
–
–
MH1
0.55 (0.75)
71
71
71
80
0.75 (1.0)
71
71
80
90
1.1 (1.5)
71
71
80
90
1.5 (2.0)
90
71
90
100
MH2
2.2 (3.0)
90
90
90
100
3 (4.0)
90
90
100
112
4 (5.0)
112
90
112
112
MH3
5.5 (7.5)
112
112
112
132
7.5 (10)
Table 6.3 Motor Frame Size Corresponding to FCP 106 Enclosure
6.1.3 FCP 106 Dimensions
195NA418.10
CC
B
A
a
X
Y
Illustration 6.2 FCP 106 Dimensions
Enclosure
type
Power
1)
[kW (hp)]
Length
[mm (in)]
Width
[mm (in)]
Height
[mm (in)]
Cable gland
diameter
Mounting
hole
Normal lid
High lid for
VLT
®
PROFIBUS DP
MCA 101
option
3x380–480 V
A
a
B
C
C
X
Y
MH1
0.55–1.5 (0.75–2.0) 231.4 (9.1) 130 (5.1) 162.1 (6.4) 106.8 (4.2)
121.4 (4.8)
M20
M20
M6
MH2
2.2–4.0 (3.0–5.0) 276.8 (10.9) 166 (6.5) 187.1 (7.4) 113.2 (4.5)
127.8 (5.0)
M20
M20
M6
MH3
5.5–7.5 (7.5–10)
321.7 (12.7) 211 (8.3) 221.1 (8.7) 123.4 (4.9)
138.1 (5.4)
M20
M25
M6
Table 6.4 FCP 106 Dimensions
1) Power ratings relate to NO, see chapter 6.2 Electrical Data.
Specifications
VLT
®
DriveMotor FCP 106/FCM 106
60
Danfoss A/S © 06/2016 All rights reserved.
MG03M202
6
6
Содержание VLT DriveMotor FCP 106
Страница 1: ...ENGINEERING TOMORROW Design Guide VLT DriveMotor FCP 106 FCM 106 vlt drives danfoss com...