15-92 Defined Parameters
0 N/A
All set-ups
FALSE
0
Uint16
15-93 Modified Parameters
0 N/A
All set-ups
FALSE
0
Uint16
5.2.15 16-** Data Readouts
Param
eter
numb
er
Parameter description
Default value
4 set-up
Change
during
operation
Conversion
index
Type
16-0* General Status
16-00 Control Word
0 N/A
All set-ups
FALSE
0
V2
16-01 Reference [Unit]
0 ReferenceFeedbackUnit
All set-ups
FALSE
-3
Int32
16-02 Reference %
0 %
All set-ups
FALSE
-1
Int16
16-03 Status Word
0 N/A
All set-ups
FALSE
0
V2
16-05 Main Actual Value [%]
0 %
All set-ups
FALSE
-2
N2
16-09 Custom Readout
0 CustomReadoutUnit
All set-ups
FALSE
-2
Int32
16-1* Motor Status
16-10 Power [kW]
0 kW
All set-ups
FALSE
1
Int32
16-11 Power [hp]
0 hp
All set-ups
FALSE
-2
Int32
16-12 Motor Voltage
0 V
All set-ups
FALSE
-1
Uint16
16-13 Frequency
0 Hz
All set-ups
FALSE
-1
Uint16
16-14 Motor current
0 A
All set-ups
FALSE
-2
Int32
16-15 Frequency [%]
0 %
All set-ups
FALSE
-2
N2
16-16 Torque [Nm]
0 Nm
All set-ups
FALSE
-1
Int16
16-17 Speed [RPM]
0 RPM
All set-ups
FALSE
67
Int32
16-18 Motor Thermal
0 %
All set-ups
FALSE
0
Uint8
16-20 Motor Angle
0 N/A
All set-ups
TRUE
0
Uint16
16-21 Torque [%] High Res.
0 %
All set-ups
FALSE
-1
Int16
16-22 Torque [%]
0 %
All set-ups
FALSE
0
Int16
16-24 Calibrated Stator Resistance
0.0000 Ohm
All set-ups
TRUE
-4
Uint32
16-3* Drive Status
16-30 DC Link Voltage
0 V
All set-ups
FALSE
0
Uint16
16-34 Heatsink Temp.
0 °C
All set-ups
FALSE
100
Uint8
16-35 Inverter Thermal
0 %
All set-ups
FALSE
0
Uint8
16-36 Inv. Nom. Current
ExpressionLimit
All set-ups
FALSE
-2
Uint32
16-37 Inv. Max. Current
ExpressionLimit
All set-ups
FALSE
-2
Uint32
16-38 SL Controller State
0 N/A
All set-ups
FALSE
0
Uint8
16-39 Control Card Temp.
0 °C
All set-ups
FALSE
100
Uint8
16-40 Logging Buffer Full
[0] No
All set-ups
TRUE
–
Uint8
16-45 Motor Phase U Current
0 A
All set-ups
TRUE
-2
Int32
16-46 Motor Phase V Current
0 A
All set-ups
TRUE
-2
Int32
16-47 Motor Phase W Current
0 A
All set-ups
TRUE
-2
Int32
16-48 Speed Ref. After Ramp [RPM]
0 RPM
All set-ups
FALSE
67
Int32
16-49 Current Fault Source
0 N/A
All set-ups
TRUE
0
Uint8
16-5* Ref. & Feedb.
16-50 External Reference
0 N/A
All set-ups
FALSE
-1
Int16
16-51 Pulse Reference
0 N/A
All set-ups
FALSE
-1
Int16
16-52 Feedback[Unit]
0 ReferenceFeedbackUnit
All set-ups
FALSE
-3
Int32
16-53 Digi Pot Reference
0 N/A
All set-ups
FALSE
-2
Int16
16-57 Feedback [RPM]
0 RPM
All set-ups
FALSE
67
Int32
16-6* Inputs & Outputs
16-60 Digital Input
0 N/A
All set-ups
FALSE
0
Uint16
16-61 Terminal 53 Switch Setting
[0] Current
All set-ups
FALSE
–
Uint8
16-62 Analog Input 53
0 N/A
All set-ups
FALSE
-3
Int32
Parameter Lists
VLT® AutomationDrive FC 361
174
Danfoss A/S © 03/2019 All rights reserved.
MG06J202
5
5