5.2.9 8-** Comm. and Options
Param
eter
numb
er
Parameter description
Default value
4 set-up
Change
during
operation
Conversion
index
Type
8-0* General Settings
8-01
Control Site
[0] Digital and ctrl.word
All set-ups
TRUE
–
Uint8
8-02
Control Word Source
ExpressionLimit
All set-ups
TRUE
–
Uint8
8-03
Control Word Timeout Time
1 s
1 set-up
TRUE
-1
Uint32
8-04
Control Word Timeout Function
ExpressionLimit
1 set-up
TRUE
–
Uint8
8-05
End-of-Timeout Function
[1] Resume set-up
1 set-up
TRUE
–
Uint8
8-06
Reset Control Word Timeout
[0] Do not reset
All set-ups
TRUE
–
Uint8
8-07
Diagnosis Trigger
[0] Disable
2 set-ups
TRUE
–
Uint8
8-08
Readout Filtering
ExpressionLimit
All set-ups
TRUE
–
Uint8
8-1* Ctrl. Word Settings
8-10
Control Word Profile
[0] FC profile
All set-ups
TRUE
–
Uint8
8-13
Configurable Status Word STW
[1] Profile default
All set-ups
TRUE
–
Uint8
8-14
Configurable Control Word CTW
[1] Profile default
All set-ups
TRUE
–
Uint8
8-19
Product Code
ExpressionLimit
1 set-up
TRUE
0
Uint32
8-3* FC Port Settings
8-30
Protocol
[0] FC
1 set-up
TRUE
–
Uint8
8-31
Address
1 N/A
1 set-up
TRUE
0
Uint8
8-32
FC Port Baud Rate
ExpressionLimit
1 set-up
TRUE
–
Uint8
8-33
Parity / Stop Bits
[0] Even Parity, 1 Stop Bit
1 set-up
TRUE
–
Uint8
8-34
Estimated cycle time
0 ms
2 set-ups
TRUE
-3
Uint32
8-35
Minimum Response Delay
10 ms
1 set-up
TRUE
-3
Uint16
8-36
Max Response Delay
ExpressionLimit
1 set-up
TRUE
-3
Uint16
8-37
Max Inter-Char Delay
ExpressionLimit
1 set-up
TRUE
-5
Uint16
8-4* FC MC protocol set
8-40
Telegram Selection
[1] Standard telegram 1
2 set-ups
TRUE
–
Uint8
8-41
Parameters for Signals
0
All set-ups
FALSE
–
Uint16
8-42
PCD Write Configuration
ExpressionLimit
2 set-ups
TRUE
0
Uint16
8-43
PCD Read Configuration
ExpressionLimit
2 set-ups
TRUE
0
Uint16
8-5* Digital/Bus
8-50
Coasting Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-51
Quick Stop Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-52
DC Brake Select
ExpressionLimit
All set-ups
TRUE
–
Uint8
8-53
Start Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-54
Reversing Select
ExpressionLimit
All set-ups
TRUE
–
Uint8
8-55
Set-up Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-56
Preset Reference Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-57
Profidrive OFF2 Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-58
Profidrive OFF3 Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
8-8* FC Port Diagnostics
8-80
Bus Message Count
0 N/A
All set-ups
TRUE
0
Uint32
8-81
Bus Error Count
0 N/A
All set-ups
TRUE
0
Uint32
8-82
Slave Messages Rcvd
0 N/A
All set-ups
TRUE
0
Uint32
8-83
Slave Error Count
0 N/A
All set-ups
TRUE
0
Uint32
8-84
Slave Messages Sent
0 N/A
All set-ups
TRUE
0
Uint32
8-85
Slave Timeout Errors
0 N/A
All set-ups
TRUE
0
Uint32
8-88
Reset FC port Diagnostics
[0] Do not reset
All set-ups
TRUE
–
Uint8
8-9* Bus Jog
8-90
Bus Jog 1 Speed
ExpressionLimit
All set-ups
TRUE
67
Uint16
Parameter Lists
VLT® AutomationDrive FC 361
168
Danfoss A/S © 03/2019 All rights reserved.
MG06J202
5
5