1-53 Model Shift Frequency
Range:
Function:
between Flux model 1 and Flux
model 2; or shift between Variable
Current mode and Flux model 2.FC
302 only.
This parameter cannot be adjusted
while the motor is running.
Flux Model 1 – Flux model 2
This model is used when
is set to
Speed closed
loop
[1] or
Torque
[2] and
is set to
Flux w/motor
feedback
[3]. With this parameter it is
possible to make an adjustment of
the shifting point where FC 302
changes between Flux model 1 and
Flux model 2, which is useful in some
sensitive speed and torque control
applications.
P 1-53
130BA146.11
f
out
f
N,M
x 0.125
f
N,M
x 0.1
Flux model 2
Flux model 1
Illustration 3.2
= [1] Speed closed loop or [2]
Torque and
= [3] Flux w/motor
feedback
Variable Current - Flux model -
Sensorless
This model is used when
is set to
Speed open
loop
[0] and
is set to
Flux sensorless
[2].
In speed open loop in flux mode, the
speed is determined from the current
measurement.
Below f
norm
x 0.1, the frequency
converter runs on a Variable Current
model. Above f
norm
x 0.125 the
frequency converter runs on a Flux
model.
1-53 Model Shift Frequency
Range:
Function:
P 1-53
130BA147.10
x 0.1
Variable
current
model
Flux model 2
f
out
f
N,M
f
N,M
x 0.125
Illustration 3.3
= [0] Speed open loop,
= [2]
Flux sensorless
1-54 Voltage reduction in fieldweakening
Range:
Function:
0 V
*
[0 - 100 V] The value of this parameter will reduce the
maximal voltage available for the flux of the
motor in fieldweakning, giving more voltage
available for torque. Be aware that too high
value may give stall problems at high speed.
1-55 U/f Characteristic - U
Range:
Function:
Application
dependent
*
[0.0 -
1000.0 V]
Enter the voltage at each frequency
point to manually form a U/f charac-
teristic matching the motor.
The frequency points are defined in
.
This parameter is an array
parameter [0-5] and is only
accessible when
is set to
U/f
[0].
1-56 U/f Characteristic - F
Range:
Function:
Application
dependent
*
[Application
dependant]
Enter the frequency points to
manually form a U/f-charac-
teristic matching the motor.
The voltage at each point is
defined in
This parameter is an array
parameter [0-5] and is only
accessible when
is set to
U/f
[0].
Parameter Descriptions
FC 300 Programming Guide
MG.33.MB.02 - VLT
®
is a registered Danfoss trademark
39
3
3
Содержание VLT AutomationDrive FC 300
Страница 1: ...MAKING MODERN LIVING POSSIBLE Programming Guide VLT AutomationDrive...
Страница 218: ...www danfoss com drives MG33MB02 130R0334 MG33MB02 Rev 2010 10 07...
Страница 219: ......