4.1.19 17-** Motor Feedb.Option
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
17-1* Inc. Enc. Interface
17-10 Signal Type
[1] RS422 (5V TTL)
All set-ups
FALSE
-
Uint8
17-11 Resolution (PPR)
1024 N/A
All set-ups
FALSE
0
Uint16
17-2* Abs. Enc. Interface
17-20 Protocol Selection
[0] None
All set-ups
FALSE
-
Uint8
17-21 Resolution (Positions/Rev)
App.Dependent
All set-ups
FALSE
0
Uint32
17-24 SSI Data Length
13 N/A
All set-ups
FALSE
0
Uint8
17-25 Clock Rate
App.Dependent
All set-ups
FALSE
3
Uint16
17-26 SSI Data Format
[0] Gray code
All set-ups
FALSE
-
Uint8
17-34 HIPERFACE Baudrate
[4] 9600
All set-ups
FALSE
-
Uint8
17-5* Resolver Interface
17-50 Poles
2 N/A
1 set-up
FALSE
0
Uint8
17-51 Input Voltage
7.0 V
1 set-up
FALSE
-1
Uint8
17-52 Input Frequency
10.0 kHz
1 set-up
FALSE
2
Uint8
17-53 Transformation Ratio
0.5 N/A
1 set-up
FALSE
-1
Uint8
17-56 Encoder Sim. Resolution
[0] Disabled
1 set-up
FALSE
-
Uint8
17-59 Resolver Interface
[0] Disabled
All set-ups
FALSE
-
Uint8
17-6* Monitoring and App.
17-60 Feedback Direction
[0] Clockwise
All set-ups
FALSE
-
Uint8
17-61 Feedback Signal Monitoring
[1] Warning
All set-ups
TRUE
-
Uint8
Parameter Lists
FC 300 Programming Guide