FC 300 CANopen
50
MG.33.J1.02 VER. 050301 – VLT is a registered Danfoss trademark
Parameter List
PNU
Parameter
Default value
Range
Conversion Data
#
Designation
index
type
8-01
Control Site
Dig. and ctrl. word
[0]
[0 - 2]
-
5
8-02
Control Word Source
FC RS485 [1]
[0 - 6]
-
5
8-03
Control Word Timeout Time 1.0 s
0.1 - 18000 -1
7
8-04
Control Word Timeout
Function
Off [0]
[0 - 10]
-
5
8-05
End-of-timeout Function
Hold set-up [0]
[0 - 1]
-
5
8-06
Reset Control Word
Timeout
Do not reset [0]
[0 - 1]
-
5
8-07
Diagnosis Trigger
Disable [0]
[0 - 3]
-
5
8-10
Control Word Profile
FC profile [0]
[0 - x]
-
5
8-50
Coasting Select
Logic OR [3]
[0 - 3]
-
5
8-51
Quick Stop Select
Logic OR [3]
[0 - 3]
-
5
8-52
DC Brake Select
Logic OR [3]
[0 - 3]
-
5
8-53
Start Select
Logic OR [3]
[0 - 3]
-
5
8-54
Reversing Select
Logic OR [3]
[0 - 3]
-
5
8-55
Set-up Select
Logic OR [3]
[0 - 3]
-
5
8-56
Preset Reference Select
Logic OR [3]
[0 - 3]
-
5
8-90
Bus Jog 1 Speed
100 rpm
0 - par.4-13 67
6
8-91
Bus Jog 2 Speed
200 rpm
0 - par.4-13 67
6
10-00 CAN
Protocol
CANopen [0]
[0 ]
- 5
10-01
Baud Rate Select
125 Kbps [20]
[16 – 22]
-
5
10-02
Drive Node ID
127
0 - 127
0
5
10-05
Readout Transmit Error
Counter
0
0 - 255
0
5
10-06
Readout Receive Error
Counter
0
0 - 255
0
5
10-07
Readout Bus Off Counter
0
0 - 255
0
6
10-31
Store Data Values
Off [0]
[0 - 2]
-
5
10-32
CANopen revision
0
0 - 65535
-
6
10-33
Store Always
Off [0]
[0 - 1]
-
5
10-40
CANopen Process Data
Config. Write
None [0]
[0 - 17]
10-41
CANopen Process Data
Config. Read
None [0]
[0 - 48]
15-60
Option Mounted
CANopen
16-48
Com Option STW
[0 - 7]
16-90
Alarm Word
0
0 - FFFF
0
7
16-92
Warning Word
0
0 – FFFF
0
7