AKD 5000
Operation of the
AKD
■
Display mode
In normal operation, up to 4 different operating
variables can be indicated continuously: 1.1 and 1.2
and 1.3 and 2, and in line 4 the present operating
status or alarms and warnings that have arisen.
VAR 2
SETUP
1
STATUS
VAR 1.1 VAR 1.2 VAR 1.3
■
Display mode - selection of read-outstate
There are three options in connection with the
choice of read-out state in the Display mode - I, II
and III. The choice of read-out state determines the
number of operating variables read out.
Read-out state:
I:
II:
III:
Line 1
Description
for operating
variable in line 2
Data value for
3 operating
variables in line
1
Description for
3 operating
variables in line
1
The table below gives the units linked to the variables
in the first and second line of the display.
O
O
O
Op
p
p
pe
e
e
errrra
a
a
attttiiiin
n
n
ng
g
g
g v
vv
va
a
a
arrrriiiia
a
a
ab
b
b
blllle
e
e
e::::
U
U
U
Un
n
n
niiiitttt::::
Reference
[%]
Reference
[unit]
Feedback
[unit]
Frequency
[Hz]
Frequency x scaling
[-]
Motor current
[A]
Torque
[%]
Power
[kW]
Power
[HP]
Output energy
[kWh]
Motor voltage
[V]
DC-link voltage
[V]
Motor thermal load
[%]
AKD thermal load
[%]
Hours run
[Hours]
Input status, dig. Input
[Binary code]
Input status, analogue terminal 53
[V]
Input status, analogue terminal 54
[V]
Input status, analogue terminal 60
[mA]
Pulse reference
[Hz]
External reference
[%]
Status word
[Hex]
Brake effect/2 min.
[kW]
Brake effect/sec.
[kW]
Heat sink temp.
[ºC]
Alarm word
[Hex]
Control word
[Hex]
Warning word 1
[Hex]
Extended status word
[Hex]
Communication option card warning
[Hex]
RPM
[min
-1
]
RPM x scaling
[ - ]
Operating variables 1.1 and 1.2 and 1.3 in the first
line, and operating variable 2 in the second line are
selected via parameter 009, 010, 011 and 012.
•
Read-out state I:
This read-out state is standard after starting
up or after initialisation.
50.0 Hz
FREQUENCY
MOTOR IS RUNNING
Line 2 gives the data value of an operating variable with
related unit, and line 1 provides a text which explains
line 2, cf. table. In the example, Frequency has
been selected as variable via parameter 009. During
normal operation another variable can immediately
be read out by using the [+/-] keys.
•
Read-out state II:
Switching between read-out states I and II is effected
by pressing the [DISPLAY / STATUS] key.