AKD 5000
Technical
data
Compact, Mains supply 3 x 380 - 500 V
According to international requirements
A
A
A
AK
K
K
KD
D
D
D tttty
yy
yp
p
p
pe
e
e
e
5
5
5
50
0
0
03
3
3
32
2
2
2
5
5
5
50
0
0
04
4
4
42
2
2
2
5
5
5
50
0
0
05
5
5
52
2
2
2
5
5
5
50
0
0
06
6
6
62
2
2
2
N
N
N
No
o
o
orrrrm
m
m
ma
a
a
allll o
o
o
ov
vv
ve
e
e
errrrllllo
o
o
oa
a
a
ad
d
d
d tttto
o
o
orrrrq
q
q
qu
u
u
ue
e
e
e ((((1
1
1
11
1
1
10
0
0
0 %
%
%
%))))::::
Output current
I
N
[A] (380-440 V)
61
73
90
106
I
MAX
(60 s) [A] (380-440 V)
67.1
80.3
99
117
I
N
[A] (441-500 V)
54
65
78
106
I
MAX
(60 s) [A] (441-500 V)
59.4
71.5
85.8
117
Output
S
N
[kVA] (380-440 V)
46.5
55.6
68.6
80.8
S
N
[kVA] (441-500 V)
46.8
56.3
67.5
91.8
Typical shaft output
P
N
[kW]
30
37
45
55
75 @
500 V
Typical shaft output
P
N
[HP]
40
50
60
75
100 @
500 V
H
H
H
Hiiiig
g
g
gh
h
h
h o
o
o
ov
vv
ve
e
e
errrrllllo
o
o
oa
a
a
ad
d
d
d tttto
o
o
orrrrq
q
q
qu
u
u
ue
e
e
e ((((1
1
1
16
6
6
60
0
0
0 %
%
%
%))))::::
Output current
I
N
[A] (380-440 V)
44
61
73
90
I
MAX
(60 s) [A] (380-440 V)
70.7
97.6
116.8
135
I
N
[A] (441-500 V)
41.4
54
65
80
I
MAX
(60 s) [A] (441-500 V)
66.2
86
104
120
Output
S
N
[kVA] (380-440 V)
33.5
46.5
55.6
68.6
S
N
[kVA] (441-500 V)
35.9
46.8
56.3
69.3
Typical shaft output
P
N
[kW]
22
30
37
45
55 @
500 V
Typical shaft output
P
N
[HP]
30
40
50
60
75 @
500 V
Max. cable cross-section to motor,
IP 54
35/2
35/2
50/0
50/0
brake and loadsharing [mm
2
]/[AWG]
2)5)
IP20
35/2
35/2
50/0
50/0
Min. cable cross-section to motor,
brake and loadsharing [mm
2
]/[AWG]
10/8
10/8
16/6
16/6
Rated input current
I
L,N
[A] (380 V)
60
72
89
104
I
L,N
[A] (460 V)
53
64
77
104
Max. cable cross-section
IP 54
35/2
35/2
50/0
50/0
power[mm
2
]/[AWG]
2) 5)
IP 20
35/2
35/2
50/0
50/0
Max. pre-fuses
[-]/UL
1)
[A]
80/80
100/100 125/125 160/150
Pre-fuse SMPS
[-]/UL
6)
[A]
4.0/4.0
4.0/4.0
4.0/
4.0
4.0/4.0
Efficiency
0.96
0.96
0.96
0.96
Weight IP 20 EB
[kg]
28
41
42
43
Weight IP 54
[kg]
54
56
56
60
Power loss at max. load.
- high overload torque
(160 %)
[W]
768
1065
1275
1571
- normal overload
torque (110 %)
[W]
1065
1275
1571
1851
Enclosure
IP
20/IP54
IP
20/IP54
IP
20/IP54
IP
20/IP54
1. For type of fuse see section
Fuses.
2. American Wire Gauge.
3. Measured using 30 m screened motor cables at rated load and rated frequency.
4. Min. cable cross-section is the smallest cable cross-section allowed to be fitted on the terminals to comply with IP 20.
Always comply with national and local regulations on min. cable cross-section.
5. Aluminium cables with cross-section above 35 mm
2
must be connected by use of a AI-Cu connector.
6. If UL/cUL is to be complied with, Ferraz shawmut type FA Y85443, Danfoss ordering no. 612Z1182 must be used.
MG.50.R3.02 -