52
Piranha4 8K Camera Color User's Manual
03-032-20156-00
Teledyne DALSA
Name
ExposureTime
Display Name ―Exposure Time‖
Name Space
Standard
Visibility
Beginner
Access
Read-Write
Type
Float
Units
Micro-seconds
Values
11 to 3000
Description
Maximum exposure time is limited by the line rate.
Name
MeasureExposureTime
Display Name "Measured Exposure Time‖
Name Space
Custom
Visibility
Beginner
Access
Read-only
Type
Integer
Units
Nano-seconds
Values
11,000 to 300,000
Name
ScanDirectionSource
Display Name "Direction Source‖
Name Space
Standard
Visibility
Beginner
Access
Read-Write
Type
Enumeration
Values
―Internal‖
- Scan direction controlled by SensorScanDirection
―External‖
- Scan direction controlled by CC3
Description
CC3 low selects forward, high selects reverse
Name
SensorScanDirection
Display Name "Internal Direction‖
Name Space
Standard
Visibility
Beginner
Access
Read-Write
Type
Enumeration
Values
"Forward"
"Reverse"
Description
This feature is used with automatically loading new settings on change of direction