8
Piranha4 8K Camera Color User's Manual
03-032-20156-00
Teledyne DALSA
Compliance
Regulatory Compliance
CE and RoHS; GenICam
*At the time of this release, CamExpert does not accommodate color Deca 9.1 mode. Contact Customer
Support if you are interested in evaluating a camera using this mode.
**
F-mount lenses are optimized for a maximum image circle of 43.2 mm. However, the P4-8k sensor is
57.67mm long. Using an F-mount lens will generate a good image for the center 6008 pixels. However
pixels beyond this range may suffer from optical distortion caused by the lens. If an application requires
the use of an F-mount lens with P4-8K cameras, contact Customer Support for additional details
regarding the use of F-mount lenses and for access to a suitable F-mount-to-M72 adapter.
Operating Ranges
Performance
Red
Green
Blue
Dynamic Range
62.5 dB
62.5 dB
62.5 dB
Random Noise
0.186 DN** rms
0.186 DN** rms
0.186 DN** rms
Broadband Responsivity
3.2 DN/(nJ/cm2)
4.4 DN/(nJ/cm2)
2.2 DN/(nJ/cm2)
Gain
1x to 10x Nominal Range (not including individual RGB gains for white balance)
DC Offset
<1 DN
<1 DN
<1 DN
PRNU
<2% @50% Sat
<2% @50% Sat
<2% @50% Sat
FPN
< 3 DN
< 3 DN
< 3 DN
SEE
78 nJ / cm2
56 nJ / cm2
113 nJ / cm2
NEE
58 pJ / cm2
42 pJ / cm2
84 pJ / cm2
Antiblooming
> 100 x Saturation
Integral non-linearity
< 2% DN
**DN = digital number
Test Conditions:
Values measured using 8-bit, 1x gain.
10 kHz line rate
Light source: white LED
No white balancing
Front plate temperature: 45º C
Certifications
Compliance
EN 55011, FCC Part 15, CISPR 11, and ICES-003 Class A Radiated Emissions Requirements.
EN 55024, and EN 61326-1 Immunity to Disturbance.
RoHS per EU Directive 2002/95/EC and WEEE per EU Directive 2002/96/EC and China Electronic Industry
Standard SJ/T11364-2006
GenICam XML Description File, Superset of the GenICam™ Standard Features Naming Convention specification
V1.5, Camera Link Serial Communication: GenICam™ Generic Control Protocol (GenCP V1.0)
Supported Industry Standards
GenICam™
Piranha4 cameras are GenICam compliant. They implement a superset of the GenICam™ Standard
Features Naming Convention specification V1.5. This description takes the form of an XML device
description file respecting the syntax defined by the GenApi module of the GenICam™ specification. The