Xtium2-CXP PX8 User's Manual
Appendix B: Troubleshooting Problems
•
127
Figure 59: CamExpert PoCXP Parameter
•
If PoCXP is enabled in CamExpert, check that the Video status PoCXP of the respective
connection is green.
Figure 60: CamExpert Video Status Bar
Over-current protection circuit is tripped
To identify this condition:
•
Ensure a CXP camera is connected to the Xtium2-CXP board.
•
Use CamExpert and verify that the PoCXP is enabled.
Verify the Video status PoCXP of the respective connection that requires power; a red status
indicates a tripped state of the over-current protection circuit.
To confirm the tripped state, start Sapera Log Viewer and search for a message similar to the
following:
“ERR 2017/12/15 11:10:32:307
CorXtium2CXPPX8.SYS: smPoCXP[brd=0,
poCxp=0]: 24V TRIP.”
where:
brd
: indicates the index of the CXP PX8 board in the system
poCxp
: indicates the index of the CXP connector - 1
To clear the TRIP condition of the Xtium2-CXP PX8 over-current circuit
1.
Open the Sapera Log Viewer and clear its contents.
2.
Start CamExpert and set PoCXP to Disabled, then change the setting to Enable. This resets the
over-current protection circuit for the current acquisition module. If necessary, perform this
procedure for any other cameras in this condition connected to the board.
3.
If over-current condition occurs, the PoCXP Video status remains red and the Log Viewer
displays a message similar to the one above; verify that the CXP connectors attached to the
cables are in good condition. Use the following pictures as a guide.