background image

Specifications 

This following table lists the specifications of the BOA2 vision system: 

General Specifications 

Specification 

Definition 

Memory 

Storage 

2 GB Storage; 1GB Program 

Image 

Sensor 

1” CCD; 5 

μm pixel size 

Resolution 

2560 x 2048 (XA5), 1920x1440 (XA3), 1664x1216 (XA2) 

Type 

Mono Progressive Scan 

Exposure 

50 us to 1000 ms 

Acquisition 

Global Reset, full-frame integration, 25 f/s (application dependent) 

Lens 

C Mount (1” lens recommended for XA5 model) 

I/O 

Trigger 

1 opto-isolated hardware trigger input 

Software trigger via Ethernet or internal timer 

Inputs 

2 General purpose opto-isolated.  

Outputs 

3 General purpose opto-isolated 

Strobe 

1 dedicated strobe output for LED light source 

Status 

N 2 application assigned LEDs 

Network 

Ethernet 

10/100/1000 BaseT 

Serial 

RS232 

1 Port – flying leads on I/O connector 

Power 

21-30 V 

Via I/O or Lamp connectors 

Device 

300 mA maximum @ 24V (~7 Watts) 

Lamp 

300 mA maximum (BOA2 powering light source directly) 

Mechanical 

Material 

Machined Aluminum with anodize/paint finish 

Mounting 

8 x M4 plus optional mounting block 

Size 

83 mm x 66 mm x 48 mm (without lens cover) 

Environment 

Temp 

-10°C (14°F) to 50°C (122°F) Operating (-60°C to 80°C) Storage  

Protection 

IP67 with cables attached 

Shock 

TBD G 

Certification 

FCC Class A and EU CE (pending) 

Version 4.3; 2017-11-20 

28 

BOA2-XA Installation 

Содержание BOA2-XAX-INS

Страница 1: ...BOA2 XAX INS Smart Vision System with iNspect Express Software Installation Guide Version 4 3 2017 11 20 1 BOA2 XA Installation ...

Страница 2: ...al and the related documentation are prohibited except with the express written consent of Teledyne DALSA Incorporated The information in this document is subject to change without notice Teledyne DALSA Incorporated makes no representations or warranties with respect to the contents of this manual and specifically disclaims any implied warranties of merchantability or fitness for a particular purp...

Страница 3: ...This equipment generates uses and can radiate radio frequency energy and may cause harmful interference to radio communication Other IP67 This product meets the requirements for industrial applications that require IP67 wash down protection requires fitted sealing lens cover and sealing plugs on unused connectors CFR 21 Part 11 This product provides the tools needed for users to implement an audit...

Страница 4: ...tentially hazardous environment by opening the enclosure Doing so may cause serious damage User Service Warning This product has no field replaceable components Tampering with the unit will void the product warranty Warranty Teledyne DALSA warrants the BOA2 Vision System against defects in materials and workmanship for a period of twenty four 24 months from the date of delivery Teledyne DALSA and ...

Страница 5: ...are Getting Started 14 Configure the PC 15 iDiscover Utility 19 BOA2 Web Server 20 Firmware Updating 21 Application Setup 22 The BOA Emulator 23 iAssistant 24 iDisplay 25 Emulator Configurator 26 Specifications General Specifications 28 Input Specifications 29 Output Specifications 30 Input Output Control 31 Panel Link Specification 33 Serial Port Connection 34 BOA2 Mechanicals 35 PL 101 Mechanica...

Страница 6: ...ting production lines machinery or moving equipment They are supported by standard industrial M12 cordsets to further simplify and reduce implementation costs Rated for IP67 deployment when fitted with a compatible lens cover BOA2 systems can be mounted in wash down factory environments without the need for additional protective enclosures For a complete list of specifications refer to Specificati...

Страница 7: ...sociated product manuals Mounting Screw Kit M4 screws for mounting the sensor Qty 4 Component Description Cables A BVS2 E8S X A BVS2 IO12S X A BVS L5S X M12 RJ45 X coded Ethernet cordset X 5 5m 10 10m M12 single ended IO cordset X 5 5m 10 10m M12 single ended lamp cordset X 2 2m 5 5m BVS PL 101 A BVS PL101S X Panel Link breakout modules Provide convenient panel access to BOA2 I O M12 IO cordset to...

Страница 8: ...WR is identical to BOA2 PWR input 24V LAN LED Red Green Yellow Network activity Blue Warm Reset LED1 Blue Camera booted not configured no Solution file Green Solution loaded ready to run or acquisition in progress Red Camera Fault LED2 Connecting the BOA2 Vision System Camera Connectors and Indicators Blue blink Booting should stop after 20 seconds In a few releases LED2 continued to blink until t...

Страница 9: ...me Wire 1 PWR Brown 2 GND Blue 3 OUT2 White 4 OUT CMN Green 5 IN0 TRIG Pink 6 IN2 Yellow 7 IN CMN Black 8 RS232 TX Gray 9 RS 232 RX Red 10 OUT 1 Purple 11 OUT 0 Gray Pink 12 IN 1 Red Blue M12 Name Wire 1 PWR Brown 2 No connect White 3 GND Blue 4 STRB Black 5 No connect Gray M12 Name RJ45 1 MDX0 1 2 MDX0 2 3 MDX1 3 4 MDX1 6 7 MDX2 5 8 MDX2 4 5 MDX3 7 6 MDX3 8 Version 4 3 2017 11 20 9 BOA2 XA Instal...

Страница 10: ...ions the Lamp cable can be connected between the camera and a compatible LED light source The BOA2 vision system supplies power and strobe control to the external light Power is routed from camera power input to the lamp The PL 101 module is an optional module that provides a safe and convenient way to interface with BOA2 It provides an isolation barrier between the factory and the camera differen...

Страница 11: ... I O from the control panel to the breakout screw terminals on the PL 101 4 Connect the M12 12 male end of the IO PWR cordset A BVS2 IO12S X to the M12 12 female connector on the camera labeled IO PWR 5 If required connect the M12 5 lamp cable A BVS L5S between the camera LAMP connector and the light 6 Connect the Trigger and I O to the PL 101 as required for the application BOA2 System A BVS2 E8S...

Страница 12: ... BOA2 Vision System provides M4 holes on the sides front and back of the camera for convenient mounting as shown in the following illustrations Top Side Mount Back Mount Front Mount Version 4 3 2017 11 20 12 BOA2 XA Installation ...

Страница 13: ...the light ring attaches 2 Install the two nylon washers from the light ring kit into the two larger mounting holes on the inside front of the camera body 3 Screw the 4 HEX light support posts into the inside threads of the light mounting holes making sure not to knock out the nylon washers from step 1 4 Align the ring light over the four support posts and secure using the 4 screws in the light rin...

Страница 14: ...cal Area Network Click on the Setup Device hot link to change the network address Remember to keep a record of what the new address is set to BOA2 supports both DHCP and Static IP addressing preferred since the address does not change NOTE A power cycle is required before the new address will take effect 4 If you incorrectly set or forgot the new address of your BOA2 you can run the iDiscover BOA ...

Страница 15: ...Control Panel Click on System Security then click System You can use the Win Pause Break to open System Properties 2 Click on Advanced Settings or the Advanced tab 3 Under Performance click on Settings to open the Performance Options shown here 4 Click the bubble beside Adjust for Best Performance Then click the check boxes beside Smooth edges of screen fonts and Use visual styles on windows and b...

Страница 16: ...firewall back on 1 Open the Control Panel Click on System and Security Click on Windows Firewall If you get a message that says the service is not running click No do not start the firewall Skip forward to D Internet Explorer 2 Click Turn Windows Firewall on or off Click the bubble beside Off not recommended in all categories Click OK Note If you prefer to leave the Firewall on you can run the App...

Страница 17: ...r does not appear if changes have already been made to the default settings The slider does not appear on the GEVA systems because this change has already been made 5 Click the Sites button 6 Clear the check box beside Require server verification https for all sites 7 In the upper field type the IP Address of your BOA2 8 Click the Add button then click Close Version 4 3 2017 11 20 17 BOA2 XA Insta...

Страница 18: ...re is no menu bar click on Tools and select Menu bar 2 Pull down the Tools menu and select Internet Options 3 In the Internet Properties click the Advanced tab Scroll down to the Security section 4 Clear the checkbox for Enable memory protection to help mitigate online attacks in W7 or Enable Enhanced Protected Mode in W10 5 Clear the 3 checkboxes beside certificates and signatures 6 Click OK Inte...

Страница 19: ...Start programs Run type iDiscover and click OK 2 If the connecting PC has not previously been used to interface a BOA2 camera you must first install the iNspect Express emulator software Once installed the program can be invoked from the iDiscover shortcut Start programs Teledyne DALSA iNspect Express Emulator for BOA Discover BOA Cameras The left panel of the iDiscover GUI shows the MAC addresses...

Страница 20: ... The web server is the portal into the inspect Express application and can be set up to prevent unauthorized access 5 Click on the iNspect Express hot link to launch the application The camera will automatically install some software components on the client when it connects for the first time These components set up the remote access to the device 6 Using the iNspect Express software refer to the...

Страница 21: ...ciated with that account Firmware Upgrading from the Web Server BOA2 firmware may need to be updated occasionally to add new features or fix reported problems To do this click on the Upgrade Device hotlink to launch the upgrade control To upgrade simply browse to the location of the upgrade binary file obtain from your Teledyne DALSA representative on the connected PC and click the upgrade button ...

Страница 22: ... doesn t need the full sensor resolution the image window can be changed to or size This will have the added benefit of increasing performance since there are less pixels to be processed Note Partial resolution modes may not be exactly or vertical of lines 3 The image can be rotated or mirrored which can be useful if the camera is not optimally mounted Note The camera must be rebooted by clicking ...

Страница 23: ... to use the standard web browser interface After the installation is complete the following related shortcuts will be available from the windows start menu Start All Programs Teledyne DALSA iNspect Express Emulator for BOA The BOA Emulator Complementary Programs Note When you access BOA2 through this interface it is important that you maintain version compatibility between the camera and the clien...

Страница 24: ...ommand prompt enter iAssistant and click go If the Emulator is installed open the program from the windows shortcut Windows Start All Programs Teledyne DALSA iAssistant In a 64bit environment navigate to C Windows SysWOW64 right click on iassistant exe and select Run as administrator When the iAssistant application launches click the Clean button Version 4 3 2017 11 20 24 BOA2 XA Installation ...

Страница 25: ...nter iDisplay and click go or open the program from the windows shortcut if installed Start All Programs Teledyne DALSA iNspect Express Emulator for BOA iDisplay When launched for the first time the dialog on the right will prompt you to select which cameras to connect for display The list on the right shows all the cameras that were found on the network segment Click on a camera to add it to the ...

Страница 26: ...iated image window The active monitor can be changed by selecting the device IP address in the drop down menu Scrolling the left panel will expose controls for changing solutions viewing history and configuring display updates on the selected camera Note iDisplay is built on the same framework as iNspect Express and includes the same runtime controls Version 4 3 2017 11 20 26 BOA2 XA Installation ...

Страница 27: ...lator If the images don t match the standard BOA resolutions exactly select the custom resolution option and add the image dimensions The emulator installation provides some basic VGA test images to get started These are selected when the use default location box is checked The application data directories are hidden under Windows 7 but they are accessible using the browse images solutions or appl...

Страница 28: ... General purpose opto isolated Outputs 3 General purpose opto isolated Strobe 1 dedicated strobe output for LED light source Status Network 2 application assigned LEDs Network Ethernet 10 100 1000 BaseT Serial RS232 1 Port flying leads on I O connector Power 21 30 V Via I O or Lamp connectors Device 300 mA maximum 24V 7 Watts Lamp 300 mA maximum BOA2 powering light source directly Mechanical Mater...

Страница 29: ...ut to start of acquisition The active polarity of each input is configured in the iNspect Express application The camera includes a noise filter on the input which is also configurable To connect with an NPN source connect the camera trigger input pin 5 to the NPN source output and the camera common input pin 7 to PWR When the source output turns ON the camera input will be pulled down turning the...

Страница 30: ... or GND Switch Time ON 400 Microseconds OFF 80 Microseconds The active polarity of each output is configured in the iNspect Express application as detailed on the following page To connect with an NPN input source connect the camera output pin 3 10 or 11 to the NPN source input and the camera common output pin 4 to GND When the camera output turns ON the opto switch closes and OUTX 0 current flows...

Страница 31: ...sed either as a Trigger or general purpose input When used for triggering the polarity of this input is programmable BOA2 inputs are available to the script tool for synchronizing with external events Output Control via iNspect Express The iNspect application provides two options for controlling the outputs on BOA2 These are selected in the Control panel of the GUI as shown below Click on the GUI ...

Страница 32: ...result is TRUE and the total inspection time is less than the pulse offset from the trigger If the pulse offset is too short BOA2 will not generate a pass pulse even if the inspection passes In this case BOA2 will always generate a FAIL pulse if FAIL is selected on the second output This would result in false rejects if the output is being used to control a directional device Min Pulse Offset Expo...

Страница 33: ...d 24 V maximum Current GPO 0 1 200 mA max 20 C Protection Fuse PTC fuses to 200 mA at 20 C or 150 mA at 70 C Common ICMN OCMN PWR or GND as wired on respective OPTOs Switch Time GPO 0 1 800 Microseconds ON or OFF includes camera switch time PL 101 Connections I O connection to BOA2 Manual Trigger for debugging Control panel I O connections 9 pin DSUB for serial connection O U T 0 RS 232 M12 O U T ...

Страница 34: ... Refer to the iNspect Express Software Users Manual for details BOA2 I O M12 12 Connector Pin Name Color 9 RS232 RX White 2 GND Blue 8 RS232 TX Gray 1 4 Not required Electrically three 3 signals are required to make a serial port connection between BOA2 and another device as shown below RS232 is a point to point connection so the Receive and Transmit lines must be crossed in the cable 3rd Party DS...

Страница 35: ...BOA2 Mechanical Dimensions Side View Back View Side View Bottom View Note All dimensions in mm Version 4 3 2017 11 20 35 BOA2 XA Installation ...

Страница 36: ...PL 101 Mechanical Dimensions Side View Top View Note All dimensions in mm Version 4 3 2017 11 20 36 BOA2 XA Installation ...