When the application is set up and stored on the camera, the Ethernet connection can
be disconnected and the inspection will run autonomously (providing you are not
communicating with 3
rd
party equipment using Ethernet)
The camera can store over 500 solutions in its flash storage memory. These solutions
can be switched through network commands, or through established PLC register
connections or through the iNspect Express application interface or API.
The camera administrator can setup user accounts with various levels of access
privilege. With password control enabled, the web server will prompt users for a valid
login and the application will only expose controls associated with that account.
Firmware Upgrading from the Web Server
BOA2 firmware may need to be updated occasionally to add new features or fix
reported problems. To do this, click on the “Upgrade Device” hotlink to launch the
upgrade control. To upgrade, simply browse to the location of the upgrade binary file
(obtain from your Teledyne DALSA representative) on the connected PC and click the
upgrade button.
Note: Export your saved solution files before upgrading the firmware.
The upgrade control also supports backup and restore of the entire camera image. This
is useful for safekeeping and camera replication.
Note: An alternative upgrade utility called “iUpgrade All” is also accessible through the
Window’s start menu if the BOA2 emulator is installed. This is an expanded utility that
supports uploading a customer logo to the camera.
Version 4.3; 2017-11-20
21