Output Specifications
The BOA2 vision system provides three (3) dedicated opto-isolated, solid state relay
outputs and a separate dedicated light strobe (pin 2 of lamp connector).
Specification
Definition
Voltage (Vin)
Load
30V maximum (lamp voltage = Vin-0.56V)
Current
GPO[0:2]
200 mA max @ 20°C (drives to OCMN when active)
STRB
200 mA max (drives to Vin-1V when active)
NOTE: Strobe timing selected in iNspect Express Sensor Panel
Protection
Fuse
PTC fuses to 200 mA at 20°C or 150 mA at 70°C
Common pin
Out
PWR or GND
Switch Time
ON
400 Microseconds
OFF
80 Microseconds
The active polarity of each output is configured in the iNspect Express application as
detailed on the following page.
To connect with an NPN input source, connect the camera output (pin 3, 10 or 11) to the
NPN source input and the camera common output (pin 4) to GND. When the camera
output turns ON, the opto switch closes and OUTX = 0 (current flows through load).
To connect with an PNP input source, connect the camera output (pin 3, 10 or 11) to the
PNP source input and the camera common output (pin 4) to PWR. When the camera
output turns ON, the opto switch closes and OUTX = output common.
Output Diagram
Version 4.3; 2017-11-20
30
BOA2-XA Installation