Installation
This section details how to connect the BOA2 vision system with its associated
components and factory environment.
Definitions
Designator
LAN
10/100/1000 BaseT Ethernet connection. Provides the primary interface for
configuring the camera, developing the application and monitoring results.
I/O PWR
Provides access to the camera I/O – 3 IN, 3 OUT, RS232. Also provides
PWR input (12-30V).
LAMP
Provides PWR and strobe control to a local LED light source.
NOTE: Lamp
PWR is identical to BOA2 PWR input (24V).
LAN LED
Red/Green/Yellow = Network activity
Blue = Warm Reset
LED1
Blue = Camera booted, not configured (no Solution file)
Green = Solution loaded, ready to run, or acquisition in progress.
Red = Camera Fault
LED2
Connecting the BOA2 Vision System
Camera Connectors and Indicators
Blue blink = Booting (should stop after 20 seconds). In a few releases LED2
continued to blink until the first trigger if a solution that requires a trigger
is auto-loaded at boot. Fixed in release 2006.
Green = Inspection Pass (runtime)
Blue = Inspection Recycle (runtime);
Red = Inspection Fail (runtime)
Off = Waiting for trigger (runtime)