MiniMax
Bolt Tension Monitor
135
3) Press the
and
arrow keys multiple times to scroll the value. When
the correct
Step Size
is being displayed,
proceed to step 8
.
4)
Alternatively
, press the
key to display the
Digits Edit Box
.
5) Press the
and
arrow keys multiple times to scroll the highlighted
value.
6) Press the
and
arrow keys multiple times to scroll the digit
locations.
7) Repeat steps
5 & 6
until the
Step Size
value is correctly displayed.
8) Press the
key to set the
Step Size
and return to the menu screen, or
to cancel entering the
Step Size
.
9) Finally, press the
key to return to the measurement screen and begin
taking readings.
12.5 Gate
The
MiniMax
is equipped with a single gate typically used to block or eliminate noise
that is present prior to the reflection from the end of the bolt, and also to force a
detection at or on a specific location or waveform. In some cases the first reflection
from the end of the bolt will not produce a suitable symmetrical waveform. However,
if the user looked further out in time (length), a reflection from a mode conversion
very well may be a better alternative signal to detect on. A mode conversion is
simply a reflection of energy that took a longer path reflecting off the sidewalls of the