IOM 1207-6 • TRAILBLAZER
®
MODEL AGZ CHILLERS
8
www.DaikinApplied.com
Installation and Application Information
General Description
Daikin Trailblazer
®
air-cooled water chillers are complete, self-
contained, automatic chillers designed for outdoor installation.
Packaged units with pump option are completely assembled,
factory wired, charged, and tested. The electrical control
center includes all equipment protection and operating controls
necessary for dependable automatic operation. Components
housed in a centrally located, weather resistant control panel
with hinged and tool-locked doors.
Trailblazer
®
units with the remote evaporator option will be
shipped as two components, the outdoor condensing unit and
the indoor evaporator on a separate skid.
NOMENCLATURE
A G Z XXX E D SM
Operating and Standby Limits
Table 1: Operating Limits for AGZ-E Chillers
Maximum standby ambient temperature
130°F (54°C)
Maximum operating standard ambient temperature
105°F (41°C)
-with optional high ambient package (see information under High Ambient Operation)
125°F (52°C)
Minimum operating ambient temperature (standard control)
32°F (0°C)
Minimum operating ambient temperature (with optional low-ambient control)
-10°F (-23°C)
Leaving chilled water temperature
40°F to 65°F (4°C to 18°C)
Leaving chilled fluid temperatures (with anti-freeze) - Note that in cases of high ambient
temperature, the lowest leaving water temperature settings may be outside of the chiller
operating envelope; consult Daikin Tools to ensure chiller is capable of the required lift.
15°F to 65°F (-9°C to 18°C)
Operating chilled water delta-T range
6°F to 16°F (3.3°C to 8.9°C)
Maximum evaporator operating inlet fluid temperature
81°F (27°C)
Maximum evaporator non-operating inlet fluid temperature
100°F (38°C)
Nameplates
Identification nameplates on the chiller:
• The unit nameplate is located on the exterior of the Unit
Power Panel. Both the Model No. and Serial No. are
located on the unit nameplate; the Serial No. is unique to
the unit. These numbers should be used to identify the
unit for service, parts, or warranty questions. This plate
also has the unit refrigerant charge and electrical ratings.
• Evaporator data plate is under insulation and contains the
serial number.
• Compressor nameplate is located on each compressor
and gives pertinent electrical information.
WARNING
Installation is to be performed by qualified personnel who are
familiar with local codes and regulations.
CAUTION
Sharp edges on unit and coil surfaces are a potential hazard to
personal safety. Avoid contact with them.
Inspection
Check all items carefully against the bill of lading. Inspect
all units for damage upon arrival. Report shipping damage
and file a claim with the carrier. Check the unit nameplate
before unloading, making certain it agrees with the power
supply available. Daikin Applied is not responsible for physical
damage after the unit leaves the factory.
Handling
Be careful to avoid rough handling of the unit. Do not push or
pull the unit from anything other than the base while sitting on
appropriately-sized roller dollies.
To lift the unit, 2-1/2” (64mm) diameter lifting eyes are provided
on the base of the unit. Arrange spreader bars and cables to
prevent damage to condenser coils or cabinet (see
Air-Cooled
Global Design
Scroll Compressor
Application, Efficiency, Unit Type
SE = Standard Efficiency Packaged Unit
HE = High Efficiency Packaged Unit
SM = Standard Efficiency Remote Evap
HM = High Efficiency Remote Evap
Design Vintage
Nominal Tons
# of Compressors
D = Tandem per Circuit
T = Trio per Circuit