Specifications
SiBE18-821_C
18
Specifications
50 Hz, 220 - 230 - 240 V
Model
FTXS60GV1B
FTXS71GV1B
Cooling
Heating
Cooling
Heating
Rated Capacity
6.0 kW Class
7.1 kW Class
Front Panel Color
White
White
Airflow Rates
m³/min
(cfm)
H
16.0 (565)
17.2 (607)
17.2 (607)
19.5 (689)
M
13.5 (477)
14.9 (526)
14.5 (512)
16.7 (590)
L
11.3 (399)
12.6 (445)
11.5 (406)
14.2 (501)
SL
10.1 (357)
11.3 (399)
10.5 (371)
12.6 (445)
Fan
Type
Cross Flow Fan
Cross Flow Fan
Motor Output
W
43
43
Speed
Steps
5 Steps, Quiet, Auto
5 Steps, Quiet, Auto
Air Direction Control
Right, Left, Horizontal, Downward
Right, Left, Horizontal, Downward
Air Filter
Removable / Washable / Mildew Proof
Removable / Washable / Mildew Proof
Running Current (Rated)
A
0.19 - 0.18 - 0.17
0.21 - 0.20 - 0.19
0.21 - 0.20 - 0.19
0.28 - 0.27 - 0.26
Power Consumption (Rated)
W
40 - 40 - 40
45 - 45 - 45
45 - 45 - 45
60 - 60 - 60
Power Factor (Rated)
%
95.7 - 96.6 - 98.0
97.4 - 97.8 - 98.7
97.4 - 97.8 - 98.7
97.4 - 96.6 - 96.2
Temperature Control
Microcomputer Control
Microcomputer Control
Dimensions (H × W × D)
mm
290 × 1,050 × 250
290 × 1,050 × 250
Packaged Dimensions (H × W × D)
mm
361 × 1,145 × 364
361 × 1,145 × 364
Weight (Mass)
kg
12
12
Gross Weight (Gross Mass)
kg
18
18
Operation
Sound
H / M / L / SL
dBA
45 / 41 / 36 / 33
44 / 40 / 35 / 32
46 / 42 / 37 / 34
46 / 42 / 37 / 34
Sound Power
dBA
61
60
62
62
Heat Insulation
Both Liquid and Gas Pipes
Both Liquid and Gas Pipes
Piping
Connection
Liquid
mm
φ
6.4
φ
6.4
Gas
mm
φ
12.7
φ
15.9
Drain
mm
φ
18.0
φ
18.0
Drawing No.
3D065512A
3D065513A
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Содержание Super Multi Plus E-Series BPMKS967B2B
Страница 1: ...Service Manual E Series SiBE18 821_C Applied Models Super Multi Plus Heat Pump...
Страница 13: ...SiBE18 821_C List of Functions 1 Part 1 List of Functions 1 Functions 2...
Страница 264: ...SA Indoor Unit FFQ FCQ FDBQ FBQ FHQ Series SiBE18 821_C 252 Operation Manual 2 Start 5s 5s 5s 5s 5s End...
Страница 471: ...SiBE18 821_C BP Unit Removal Procedure 459 Step Procedure Points Clamps Q0529...
Страница 491: ...Revision History Date News No Contents 2010 11 9 M 10013 Correction of troubleshooting flowchart AF for SkyAir models...