Specifications
SiBE18-821_C
12
Specifications
1.2
BP Unit
50 Hz, 230 V
Note:
1. BP or Indoor Unit Max. Height - BP or Indoor Unit Min. Height
→
Max. 15 m.
Set up BP and indoor unit within 15 m height difference.
2. The piping connection must be cut so as to suit the piping sizes of the indoor unit which will be connected.
The same sizes should be used for the piping on the outdoor unit.
3. ( )* : including auxiliary piping length
Model
BPMKS967B2B
BPMKS967B3B
Connectable Indoor Units
1 ~ 2 Units
1 ~ 3 Units
Casing Color
Paintingless
Power Consumption
W
10
10
Running Current
A
0.05
0.05
Refrigerant Type
R-410A
Dimension (H × W × D)
mm
180 × 294 (650)* × 350
Package Dimension (H × W × D)
mm
257 × 738 × 427
Machine Weight (Mass)
kg
7.5
8
Gross Weight (Gross Mass)
kg
11
12
Number of Wiring Connections
4 for Interunit Wiring
Piping
Connection
(Brazing)
Liquid
mm
Main:
φ
9.5 × 1 / Branch:
φ
6.4 × 2
Main:
φ
9.5 × 1 / Branch:
φ
6.4 × 3
Gas
mm
Main:
φ
19.1 × 1 / Branch:
φ
15.9 × 2
Main:
φ
19.1 × 1 / Branch:
φ
15.9 × 3
Drain
mm
Drain Processingless
Heat Insulation
Both Liquid and Gas Pipes
Max. Piping Length
m
—
Amount of Additional Charge
g/m
—
Max. Height Difference
m
—
Max. Combination
kW
14.2
20.8
Min. Combination
kW
2.0
2.0
Accessories
Installation Manual
pc.
1
Reducer
pc.
For Main
Liquid
1 (For I.D.
φ
6.4)
Gas
1 (For I.D.
φ
12.7)
Gas
1 (For I.D.
φ
15.9, 19.1)
For Branch
Liquid
1 (For I.D.
φ
9.5)
Gas
2 (For I.D.
φ
12.7, 9.5)
3 (For I.D.
φ
12.7, 9.5)
Hanger Metal
pc.
4
Screws
pc.
8 (M4 × 8)
Heat Insulation (2pc. is 1 set)
3 Sets
4 Sets
Binding Band
pc.
2
Drawing No.
C: 4D050058B
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Содержание Super Multi Plus E-Series BPMKS967B2B
Страница 1: ...Service Manual E Series SiBE18 821_C Applied Models Super Multi Plus Heat Pump...
Страница 13: ...SiBE18 821_C List of Functions 1 Part 1 List of Functions 1 Functions 2...
Страница 264: ...SA Indoor Unit FFQ FCQ FDBQ FBQ FHQ Series SiBE18 821_C 252 Operation Manual 2 Start 5s 5s 5s 5s 5s End...
Страница 471: ...SiBE18 821_C BP Unit Removal Procedure 459 Step Procedure Points Clamps Q0529...
Страница 491: ...Revision History Date News No Contents 2010 11 9 M 10013 Correction of troubleshooting flowchart AF for SkyAir models...