Field Settings
SiBE18-821_C
162
Test Operation and Field Settings
2.3.3 MAIN / SUB Setting when Using 2 Wired Remote Controllers
Outline
The MAIN / SUB setting is necessary when 1 indoor unit is controlled by 2 remote controllers.
When you use 2 remote controllers (control panel and separate remote controller), set one to
MAIN and the other to SUB.
Detail
The remote controllers are factory set to MAIN, so you only have to change one remote
controller from MAIN to SUB.
BRC1D528
BRC1E51A7
Step
Action
1
Insert a flat screwdriver into the groove between the upper and lower part of the
remote controller, as shown in the illustration below. Gently pry off the upper part
of the controller, working from the two possible positions.
2
Set the [MAIN / SUB changeover] switch on the PCB to “S”.
Step
Action
Remote controller
1
Put on the power for both remote
controllers.
2
Determine which one is the sub/main
remote controller.
3
When
Error code: U5 - Connection
under check Please wait for a moment
is
displayed on both remote controllers, push
and hold the [Operation mode selector]
button
of the sub remote controller for
4 seconds.
4
The sub remote controller now displays
Sub remote contrl.
Note) The main remote controller still
displays
Main remote contrl.
5
After a few seconds, the basic screen is
displayed.
(R11738)
Upper part of the
remote controller
Lower part of the
remote controller
S
M
S
M
Set the switch to SUB.
(R11739)
The switch is set to
MAIN (factory setting)
(R12880)
Connection under check
Please wait for a moment
Main remote contrl
Error code:U5
(R12881)
Connection under check
Please wait for a moment
Sub remote contrl
Содержание Super Multi Plus E-Series BPMKS967B2B
Страница 1: ...Service Manual E Series SiBE18 821_C Applied Models Super Multi Plus Heat Pump...
Страница 13: ...SiBE18 821_C List of Functions 1 Part 1 List of Functions 1 Functions 2...
Страница 264: ...SA Indoor Unit FFQ FCQ FDBQ FBQ FHQ Series SiBE18 821_C 252 Operation Manual 2 Start 5s 5s 5s 5s 5s End...
Страница 471: ...SiBE18 821_C BP Unit Removal Procedure 459 Step Procedure Points Clamps Q0529...
Страница 491: ...Revision History Date News No Contents 2010 11 9 M 10013 Correction of troubleshooting flowchart AF for SkyAir models...