10
|
Configuration
Installer reference guide
186
ERGA04~08EAV3(A) + EHBH/X04+08EA/EJ6V+9W
Daikin Altherma 3 R W
4P629085-1 – 2020.08
Domestic hot water
The following setting determines if the system can prepare domestic hot water or
not, and which tank is used. Set this setting according to the actual installation.
#
Code
Description
[9.2.1]
[E‑05]
(a)
[E‑06]
(a)
[E‑07]
(a)
▪
No DHW
No tank installed.
▪
EKHWS/E
Tank with booster heater installed at the side of
the tank.
▪
EKHWP/HYC
Tank with optional booster heater installed at
the top of the tank.
(a)
Use the menu structure instead of the overview settings. Menu structure setting [9.2.1]
replaces the following 3 overview settings:
•
[E-05]: Can the system prepare domestic hot water?
•
[E-06]: Is a domestic hot water tank installed in the system?
•
[E-07]: What kind of domestic hot water tank is installed?
In case of EKHWP, we recommend to use the following settings:
#
Code
Item
EKHWP
[9.2.1]
[E‑07]
Tank type
5:
EKHWP/HYC
N/A
[4-05]
Thermistor type
0: Automatic
[5.8]
[6-0E]
Maximum tank
temperature
≤70°C
In case of EKHWS*D* / EKHWSU*D*, we recommend to use the following settings:
#
Code
Item
EKHWS*D* / EKHWSU*D*
150/180
200/250/300
[9.2.1]
[E‑07]
Tank type
0:
EKHWS/E
5:
EKHWP/HYC
N/A
[4-05]
Thermistor type
0: Automatic
1: Type 1
[5.8]
[6-0E]
Maximum tank
temperature
≤75°C
In case of a third-party tank, we recommend to use the following settings:
#
Code
Item
Third-party tank
Coil≥1.05 m²
Coil≥1.8 m²
[9.2.1]
[E‑07]
Tank type
0:
EKHWS/E
5:
EKHWP/HYC
N/A
[4-05]
Thermistor type
0: Automatic
1: Type 1
[5.8]
[6-0E]
Maximum tank
temperature
≤75°C