9
|
Electrical installation
Installer reference guide
98
ERGA04~08EAV3(A) + EHBH/X04+08EA/EJ6V+9W
Daikin Altherma 3 R W
4P629085-1 – 2020.08
b
a
a
Stranded conductor wire
b
Round crimp-style terminal
▪
Use the following methods for installing wires:
Wire type
Installation method
Single-core wire
c b
c
a
a
A
AA´
A´
a
Curled single-core wire
b
Screw
c
Flat washer
Stranded conductor wire
with round crimp-style
terminal
c b
b
a
c
a
B
B
a
Terminal
b
Screw
c
Flat washer
Allowed
NOT allowed
Tightening torques
Item
Tightening torque (N•m)
M4 (X1M)
1.2~1.5
M4 (earth)
9.1.3 Specifications of standard wiring components
Component
06DAV3
ERGA08DAV3
ERGA04~08DAV3A
Power
supply
cable
MCA
(a)
19.9 A
24.0 A
15.9 A
Voltage
230 V
Phase
1~
Frequency
50 Hz
Wire sizes
Must comply with applicable legislation
Interconnection cable
Minimum cable section of 1.5 mm² and applicable for
230 V
Recommended field
fuse
20 A
25 A
16 A
Earth leakage circuit
breaker
Must comply with applicable legislation
Содержание ERGA04EAV3A