10/11
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.I
[D-00]
R/W
0: None
1: BSH only
2: BUH only
3: All heaters
9.I
[D-01]
R/W
0: No
1: Active open
2: Active closed
3: Smart grid
9.I
[D-02]
R/W
0: No
1: Secondary rtrn
2: Disinf. Shunt
3: Circulation Pump
4: Circulation Pump and disinf. Shunt
9.I
[D-03]
R/W
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
9.I
[D-04]
R/W
0: No
1: Pwr consmp ctrl
9.I
[D-05]
R/W
0: Forced off
1: As normal
9.I
[D-07]
R/W
0: No
1: Yes
9.I
[D-08]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
9.I
[D-09]
R/W
0: No
1: 0,1 pulse/kWh
2: 1 pulse/kWh
3: 10 pulse/kWh
4: 100 pulse/kWh
5: 1000 pulse/kWh
6: 100 pulse/kWh (PV meter)
7: 1000 pulse/kWh (PV meter)
8: 1 pulse/m³ (gas meter)
9: 10 pulses/m³ (gas meter)
10: 100 pulses/m³ (gas meter)
9.I
[D-0B]
2
9.I
[D-0C]
0
9.I
[D-0D]
0
9.I
[D-0E]
0
9.I
[E-00]
R/W (*6)
R/O (*7)
0: Reversible (*4)
1: Heating only (*3)
9.I
[E-01]
R/O
1
9.I
[E-02]
R/W (*4)
R/O (*3)
0: Reversible (*4)
1: Cooling only (*3)
9.I
[E-03]
R/W (*1)
R/O (*2)
0: no BUH (*1)
1: External BUH
2: 3V (*2)
9.I
[E-04]
R/O
0: No
1: Yes
9.I
[E-05]
R/W
0: No
1: Yes
9.I
[E-06]
R/O
0: No
1: Yes
9.I
[E-07]
R/W
0~6
0: EKHW
5: EKHWP
9.I
[E-08]
R/W
0: Disabled
1: Enabled
9.I
[E-09]
1
9.I
[E-0B]
0
9.I
[E-0C]
0
9.I
[E-0D]
0: No
1: Yes
9.I
[E-0E]
0
9.I
[F-00]
R/W
0: Disabled
1: Enabled
9.I
[F-01]
R/W
10~35°C, step: 1°C
20°C
9.I
[F-02]
R/W
3~10°C, step: 1°C
3°C
9.I
[F-03]
R/W
2~5°C, step: 1°C
5°C
9.I
[F-04]
R/O
0
9.I
[F-05]
0
9.I
[F-09]
R/W
0: Disabled
1: Enabled
9.I
[F-0A]
0
9.I
[F-0B]
0
9.I
[F-0C]
1
9.I
[F-0D]
R/W
0: Continuous
1: Sample
2: Request
--
--
What is the pump operation mode?
Above which outdoor temperature is cooling allowed?
Bottom plate heater ON temperature.
Bottom plate heater hysteresis.
Is a bottom plate heater connected?
--
Pump operation during flow abnormality.
Is a bi-zone kit installed?
--
Is glycol present in the system?
--
Pump operation allowed outside range.
--
Is the power saving function available on the outdoor unit?
Can the system prepare domestic hot water?
Is a DHW tank installed in the system?
What kind of DHW tank is installed?
Power saving function for outdoor unit.
--
--
--
Which type of unit is installed?
Which type of compressor is installed?
What is the indoor unit software type?
What is the number of backup heater steps?
Is the pump allowed to run if prefer. kWh rate PS is cut?
Is a solar kit connected?
Is an external kWh meter used for power measurement?
Is an external kWh meter used for power measurement, kWh meter used for smart
grid or a gas meter for hybrid unit?
--
--
Which heaters are permitted if prefer. kWh rate PS is cut?
Contact type of preferential kWh rate PS installation?
Which type of DHW pump is installed?
Leaving water temperature compensation around 0°C.
Is a demand PCB connected?
4P627273-1B - 2022.05
(*1) *V3/W1*
(*2) *3V3/3W1*
(*3) EDLA*
(*4) EBLA*