9
|
Electrical installation
Installer reference guide
98
EBLA09~16D + EDLA09~16D
Daikin Altherma 3 M
4P620241-1B – 2022.05
X1M
OR
1N~
3N~
L1 L2 L3 N
L N
3
Fix the cables with cable ties to the cable tie mountings.
In case of preferential kWh rate power supply
Preferential kWh rate
power supply
Wires: 1N+GND, OR 3N+GND
Maximum running current: Refer to name plate on
unit.
Separate normal kWh
rate power supply
Wires: 1N
Maximum running current: 6.3 A
Preferential kWh rate
power supply contact
Wires: 2×(0.75~1.25 mm²)
Maximum length: 50 m.
Preferential kWh rate power supply contact:
16 V DC detection (voltage supplied by PCB). The
voltage-free contact shall ensure the minimum
applicable load of 15 V DC, 10 mA.
[9.8]
Benefit kWh power supply
1
"7.3.2 To open the outdoor unit"
72].
2
Connect the preferential kWh rate power supply (1N~or 3N~ depending on
model, see name plate).
N
L N PE
Q1DI
X1M.L
X1M.L1
X1M.L2
X1M.L3
X1M.N
X1M.N
X1M.
X1M.
L3
L2
L1
N PE
Q1DI
1N~
3N~
OR
1N~, 50 Hz,
220-240 V AC
3N~, 50 Hz,
380-415 V AC