17
|
Technical data
Installer reference guide
267
EBLA09~16D + EDLA09~16D
Daikin Altherma 3 M
4P620241-1B – 2022.05
Electrical connection diagram
For more details, please check the unit wiring.
4 core
2×0.75
230 V
1
3
3
(F2B)
X2M: 5-6
A8P: X801M: 1-5
X2M: 12-13-14a
A1P: X9A
X5M: 14
X5M: 13-14
X5M: 13
A8P: X801M: 2-5
A8P: X801M: 3-5
A8P: X801M: 4-5
A4P: Y1-YC
X2M: 7-9
A4P: X1-X2
X5M: 11-12
X5M: 15-16
X2M: 3-4-14a
X2M: 1-2
X5M: 7-8
A1P: X45A
X5M: 5-6
X5M: 3-4
A4P: Y2-YC
X2M: 7-9
7
7
7
2×0.75
230 V
230 V
230 V
230 V
230 V
X7M: 5-6
230 V
A1P: X6A
A1P: X11A
230 V
230 V
230 V
230 V
Q2L
X6M
3G×2.5
X8M
230 V
230 V
A2P: X1M: C-com-H
X1M: 1-2-3
A1P: X19A
A1P: X1A
4D128841C
A3P
A11P: X1B: P2-P1
A11P: X10
MMI
A11P: X1B: +12V- –12V
X3M: 3-4-5
X3M: 1-2
X5M: 1-2
X15M: 1-2
X15M: 8-9-10
X15M: 6-7
4
4
(F1B)
(F1B)
2
2
2
X10M: 1-2
2×0.75
X10M: 3-4
2×0.75
X5M: 9-10
2×0.75
230 V
5
6
5
5
8
230 V
8
6
1
A15P: X1M: H-C-com
X2M: L-N
A2P: X1M: 1-3
2×0.75
9
A2P: X1M: 1-2
9
- In case of signal cable: keep minimum distance to power cables >5 cm
Notes:
FIELD SUPPLY
Only for KRCS01-1 or EKRSCA1
2-way valve
3-way valve
signal
2 core
signal
2 core
signal
2 core
signal
2 core
Power limitation demand input 4
Power limitation demand input 3
Power limitation demand input 2
Power limitation demand input 1
3 core
M3S (when *KHW is installed)
Selection domestic hot water – Floor heating
2 core
Clixon
2 core
Thermistor
2 core
Safety contactor
signal
R5T Thermistor water temperature
3 core
Booster heater
Domestic hot water tank
FIELD SUPPLY
OPTIONAL PART
Only for *KRP1AHTA
Only for *KRP1HB*
FIELD SUPPLY
POWER SUPPLY
HYDRO MODULE
Cooling/heating ON/OFF output
Electricity meter pulse input 1
Smart Grid contact K2A
Electricity meter pulse input 2
Smart Grid pulse meter
External thermistor (indoor or outdoor)
Circulation pump for domestic hot water
M2S for cooling mode
External heat source (e.g. boiler)
Compressor power supply for hydro: 230 V
Only for normal power supply installation
Alarm indication
signal
2 core
signal
2 core
signal
2 core
signal
2 core
Flow switch
signal
2 core
2 core
2 core
2 core
2 core
5 core
WLAN cartridge
A14P: P2-P1 user interface
Only for Human Comfort Interface
Only for *KRTW* (wired room thermostat)
5 core for C/H operation
4 core for H only operation
3 core for C/H operation
2 core for H only operation
4 core
communication
2 core
OPTIONAL PART
OPTIONAL PART
External room thermostat / Heat pump convector (main and/or additional zone)
main: X2M: 30-31-34-35
add: X2M: 30-31-34a-35a
main: X2M: 30-34-35
add: X2M: 30-34a-35a
Cooling/heating
ON/OFF output
NO valve: X2M: 3-4
Only for EKMBHBP1 (bypass valve kit)
M4S bypass valve
3 core
Changeover to
ext. heat source output
Alarm output
K3M: 2-4 + earth
X4M: L-N + earth
F1B: 2-4-6-8 + earth
2 core
5 or 3 core
signal
signal
400 or 230 V
Thermistor
Contactor
Clixon
3 core
Booster heater power supply (2.4 kW):
230 V + earth
5 or 3 core
2 core
2 core
X1M: L1-L2-L3-N-earth
or L-N-earth
Normal kWh rate power supply for hydro:
Safety thermostat Q4L
Only for preferential kWh rate power supply installation
Unit power supply:
400 V or 230 V + earth
400 or 230 V
COMPRESSOR MODULE
STANDARD PART
POWER SUPPLY
POWER SUPPLY
OPTIONAL PART
signal
signal
Only for heat pump convector
Only for high voltage Smart Grid
Only for low voltage Smart Grid
Only for high voltage Smart Grid
Smart Grid contact S11S
Only for low voltage Smart Grid
main: X2M: 30-35
add: X2M: 30-35a
main & add: X2M: 3-4
signal
4 core
External backup heater
5 core
X9M: L-N-PE
3 core
Integrated backup heater power supply (3 kW):
230 V + earth
External backup heater power supply (3/6/9 kW):
400 V or 230 V + earth
Smart Grid contact K1A
2 core
Smart Grid relay K1A
2 core
Smart Grid relay K2A
2 core
signal
Preferential kWh rate power
supply contact
FIELD SUPPLY
OPTIONAL PART
Smart Grid contact S10S
FIELD SUPPLY
HV smartgrid control supply: 230 V
R2T External sensor (floor or
ambient)
Only for *KRTETS
signal
2 core
(3m included)
Only for LAN adapter
Only for *KRTR* (wireless room thermostat)
Only for EKRTR1
Only for EKRTRB
A13P: P2-P1 LAN adapter
2 core
communication