Follow the manufacturer’s directions for service.
B
URNER
The Ultra Low NOx furnace uses a premix burner. The
burner box is sealed to achieve safe and reliable opera-
tion. There is a small viewport available on the burner
box to check for ignition and operation.
Burner Box
Figure 36
I
NDUCED
D
RAFT
AND
C
IRCULATOR
B
LOWERS
The bearings in the induced draft blower and circulator blower
motors are permanently lubricated by the manufacturer. No
further lubrication is required. Check motor windings for ac-
cumulation of dust which may cause overheating. Clean as
necessary.
C
ONDENSATE
T
RAP
AND
D
RAIN
S
YSTEM
(Q
UALIFIED
S
ERVICER
O
NLY
)
Annually inspect the drain tubes, drain trap, and field-sup-
plied drain line for proper condensate drainage. Check drain
system for hose connection tightness, blockage, and leaks.
Clean or repair as necessary.
F
LAME
S
ENSOR
(Q
UALIFIED
S
ERVICER
O
NLY
)
Under some conditions, the fuel or air supply can create a
nearly invisible coating on the flame sensor. This coating acts
as an insulator causing a drop in the flame sense signal. If the
flame sense signal drops too low the furnace will not sense
flame and will lock out. The flame sensor should be carefully
cleaned by a qualified servicer using emery cloth or steel wool.
Following cleaning, the flame sense signal should be as indi-
cated in the Specifications Sheet.
F
LUE
P
ASSAGES
(Q
UALIFIED
S
ERVICER
O
NLY
)
The heat exchanger flue passageways should be inspected at
the beginning of each heating season.
B
EFORE
L
EAVING
AN
I
NSTALLATION
•
Cycle the furnace with the thermostat at least three
times. Verify cooling and fan only operation.
•
Review the Owner’s Manual with the homeowner and
discuss proper furnace operation and maintenance.
•
Leave literature packet near furnace.
R
EPAIR
AND
R
EPLACEMENT
P
ARTS
•
When ordering any of the listed functional parts, be
sure to provide the furnace model, manufacturing, and
serial numbers with the order.
•
Although only functional parts are shown in the parts
list, all sheet metal parts, doors, etc. may be ordered
by description.
•
Parts are available from your distributor.
Functional Parts List-
Gas Valve
Blower Motor
Gas Manifold
Blower Wheel
Natural Gas Orifice
Blower Mounting Bracket
Igniter
Blower Cutoff
Flame Sensor
Blower Housing
Burner Temperature Switch Pressure Switch
Primary Limit Switch
Door Switch
Coil Front Cover
Auxiliary Limit Switch
Transformer
Integrated Control Module
Induced Draft Blower
Door Switch
Heat Exchanger with
Burner Box
Recuperator Coil
Pressure Sensor
Содержание DM96SE
Страница 37: ...37 THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 38: ...38 THIS PAGE LEFT INTENTIONALLY BLANK ...
Страница 39: ...39 THIS PAGE LEFT INTENTIONALLY BLANK ...