Troubleshooting
2.28 “
J7
” Malfunction of Receiver Outlet Liquid Pipe
Thermistor (R6T) ...................................................................................... 155
2.29 “
J8
”Malfunction of Oil Equalizing Pipe Thermistor (R7T).......................... 156
2.30 “
J9
” Malfunction of Sub-Cooling Gas Pipe Thermistor (R5T) ................... 157
2.31 “
JA
” Outdoor Unit: Malfunction of Discharge Pipe Pressure Sensor......... 158
2.32 “
JC
” Outdoor Unit: Malfunction of Suction Pipe Pressure Sensor ............. 160
2.33 “
L4
” Outdoor Unit: Malfunction of Inverter Radiating
Fin Temperature Rise............................................................................... 161
2.34 “
L5
” Outdoor Unit: Inverter Compressor Abnormal ................................... 162
2.35 “
L8
” Outdoor Unit: Inverter Current Abnormal........................................... 163
2.36 “
L9
” Outdoor Unit: Inverter Start up Error.................................................. 165
2.37 “
LC
” Outdoor Unit: Malfunction of Transmission Between Inverter
and Control PC Board .............................................................................. 166
2.38 “
P1
” Outdoor Unit: Inverter Over-Ripple Protection ................................... 168
2.39 “
P4
” Outdoor Unit: Malfunction of Inverter Radiating
Fin Temperature Rise Sensor .................................................................. 170
2.40 “
PJ
” Outdoor Unit: Faulty Field Setting after Replacing Main
PC Board or Faulty Combination of PC Board ......................................... 171
2.41 “
UO
” Outdoor Unit: Low Pressure Drop Due to Refrigerant Shortage or
Electronic Expansion Valve Failure.......................................................... 172
2.42 “
U1
” Outdoor Unit: Reverse Phase, Open Phase ...................................... 174
2.43 “
U2
” Outdoor Unit: Power Supply Insufficient or Instantaneous Failure .... 175
2.44 “
U3
” Outdoor Unit: Check Operation not executed.................................... 177
2.45 “
U4
” Malfunction of Transmission Between Indoor Units
and Outdoor Units .................................................................................... 178
2.46 “
U5
” Indoor Unit: Malfunction of Transmission Between
Remote Controller and Indoor Unit........................................................... 180
2.47 “
U7
” Indoor Unit: Malfunction of Transmission Between Outdoor Units .... 181
2.48 “
U8
” Indoor Unit: Malfunction of Transmission Between Main
and Sub Remote Controllers .................................................................... 183
2.49 “
U9
” Indoor Unit: Malfunction of Transmission Between Indoor Units
and Outdoor Units in the Same System ................................................... 184
2.50 “
UA
” Improper Combination of Indoor Units and
Outdoor Units/Indoor Units and Remote Controller.................................. 186
2.51 “
UC
” Address Duplication of Central Remote Controller ............................ 188
2.52 “
UE
” Malfunction of Transmission Between Centralized Controller
and Indoor Unit......................................................................................... 189
2.53 “
UF
” System is not Set yet ......................................................................... 191
2.54 “
UH
” Malfunction of System, Refrigerant System Address Undefined....... 192
3. Troubleshooting (OP: Central Remote Controller) ..................................194
3.1
“
M1
” PC Board Defect ................................................................................ 194
3.2
“
M8
” Malfunction of Transmission Between Optional Controllers
for Centralized Control ............................................................................. 195
3.3
“
MA
” Improper Combination of Optional Controllers
for Centralized Control ............................................................................. 197
3.4
“
MC
” Address Duplication, Improper Setting .............................................. 199
Содержание BSVQ36MVJU
Страница 16: ...SiUS39 601 Specifications 5 Part 2 Specifications 1 Specifications 6 1 1 Outdoor Units 6 1 2 Indoor Units 11 ...
Страница 115: ...Field Setting SiUS39 601 104 Test Operation ...
Страница 227: ...Troubleshooting OP Unified ON OFF Controller SiUS39 601 216 Troubleshooting ...
Страница 231: ...Piping Diagrams SiUS39 601 220 Appendix 1 Piping Diagrams 1 1 Outdoor Unit RXYQ72M 96M ...
Страница 235: ...Wiring Diagrams for Reference SiUS39 601 224 Appendix 2 2 Field Wiring RXYQ72 96MTJU C 3D042647B ...
Страница 236: ...SiUS39 601 Wiring Diagrams for Reference Appendix 225 RXYQ144 168 192MTJU C 3D050353A ...
Страница 239: ...Wiring Diagrams for Reference SiUS39 601 228 Appendix FXAQ07M 09M 12M 18M 24MVJU FXHQ12M 24M 36M 3D046039C 3D048116 ...
Страница 240: ...SiUS39 601 Wiring Diagrams for Reference Appendix 229 FXLQ12M 18M 24MVJU FXNQ12M 18M 24MVJU 3D045644A ...
Страница 249: ...Example of Connection SiUS39 601 238 Appendix ...
Страница 255: ...Method of Replacing The Inverter s Power Transistors and Diode Modules SiUS39 601 244 Appendix ...
Страница 265: ...Precautions for New Refrigerant R 410A SiUS39 601 254 Precautions for New Refrigerant R 410A ...
Страница 269: ...SiUS39 601 iv Index ...