Si18-201
Wiring
Caution Before Operation
351
(5) Follow the instruction on the
wiring nameplate to connect
the connection wires for
indoor/outdoor units in
accordance with the terminal
board numbers.
Operating Test
Follow the "operating test" as described in the manual for installation that comes with outdoor unit.
Ground
Procedure for changing the installation location
of printed wiring board
H
Screw (M5)
If the installation location of printed wiring board
needs to be changed because of the installation
conditions, perform the following:
(1) Remove the electrical equipment cover.
Loosen the screw, and slide the cover in the direction
indicated by the arrow.
(2) Loosen 4 screws shown in the figure on the below,
remove the mounting plate of the printed wiring board.
(3) Loosen and remove 2 screws fixed on
the partition board in the opposite
side.
(4) Interchange the positions of the printed
wiring board and partition board, and
then fix them with screws.
•
Do not turn ON the power until relocation and
wiring is completed.
•
When supplying power, it will automatically
recognize the vertical orientation of the
printed wiring board and change the terminal
board for the indoor unit in order starting with
A, B, and then C from above.
CAUTIONS:
The terminal board numbers
are arranged from top to
bottom in order of 3, 2, and 1.
NOTE:
Remove 4 screws.
Printed wiring board
mounting plate
Screws (2 pieces)
Connection wire for outdoor unit
Partition board
Interchange
Wire clamp 5 , Insulator 6 (accessories)
Wiring nameplate
*Fix each wire separately.
Room A
Room B
Room C
1
2
4
3
2
1
1
2
3
3
2
1
3
2
1
4
P
44
12
A1
SER. No.
3P057430-2
INDOOR UNIT
INDOOR UNIT
CONNECTION ROOM
CONNECTION ROOM
SER. No.
INDOOR UNIT
CONNECTION ROOM
SER. No.
INDOOR UNIT
CONNECTION ROOM
B2
B3
A2
A3
C1
C2
C3
A
C
1
3
4
4
12
3
C1
CONNECTION ROOM
SER. No.
SER. No.
SER. No.
INDOOR UNIT
INDOOR UNIT
INDOOR UNIT
CONNECTION ROOM
CONNECTION ROOM
C2
C3
B1
B2
B3
A1
A2
A3
A
B
C
1
2
3
Do not use tapped wires,
stand wires, extensioncords,
or starbust connections, as
they may cause overtheating,
electrical shock, or fire.
Warning
Room A
Room B
Room C
Once a screw-hole on the main unit
has had a screw hammered in,
make sure to cover it with
aluminum tape.
(This is to prevent condensation.)
Refrigerant pipe
When wire length exceed
10m, use 2.0mm wires.
Connection wire for
indoor units
H05VV, 4 wires
1.6mm or 2.0mm
When wire length exceed
10m, use 2.0mm wires.
H05VV, 4 wires
1.6mm or 2.0mm
1P058455B
Содержание BPMK928B42
Страница 9: ...Si18 201 viii Table of Contents ...
Страница 71: ...Specifications Si18 201 58 Specifications ...
Страница 206: ...Si18 201 Remote Controller Operations 193 1 1 2 FVX25 35KZ ...
Страница 207: ...Remote Controller Si18 201 194 Operations 1 1 3 FTXD25 35KZ ...
Страница 208: ...Si18 201 Remote Controller Operations 195 1 1 4 FTK FTX50 60H ...
Страница 209: ...Remote Controller Si18 201 196 Operations 1 1 5 FTKD FTXD50 60 71J ...
Страница 213: ...Remote Controller Si18 201 200 Operations 1 1 9 FHYC35 50 60 71K Optional Accessory BRC7C612WC ...
Страница 214: ...Si18 201 Remote Controller Operations 201 ...
Страница 216: ...Si18 201 Remote Controller Operations 203 ...
Страница 217: ...Remote Controller Si18 201 204 Operations ...
Страница 234: ...Si18 201 Method of Field Set Operating Test 221 2 3 Interface Adaptor for Room Airconditioner KRP928A1S ...
Страница 237: ...Method of Field Set Si18 201 224 Operating Test ...
Страница 262: ...Si18 201 Troubleshooting SkyAir Indoor Unit Service Diagnosis 249 ...
Страница 393: ...Wiring Diagrams Si18 201 380 Appendix FHYC35 50 60 71KVE9 3D005668C ...
Страница 394: ...Si18 201 Wiring Diagrams Appendix 381 FHYC35 50 60 71KV1C9 ...
Страница 395: ...Wiring Diagrams Si18 201 382 Appendix FDYM60 03FAV1 FDYM60 03FAVAL C 3D019816D OPTION ...
Страница 396: ...Si18 201 Wiring Diagrams Appendix 383 FDYM60 03FAV1C ...