15
8. INSTALLATION
8.1 Sensor unit
(1) Use the sensor unit under environmental conditions meeting the following specifications
When mounting the sensor unit, select a place where vibration can be 4 G or less (2 Hz to 2 kHz).
When selecting the sensor mounting place, also check that the mist suction port of the sensor hood
cannot be continuously blocked by a large quantity of oil.
By rotatory direction of a crankshaft and structure of the engine inside, the heavy splash of lubrication oil
occurs, and there may be the case that the oil mist is hard to come in to a detecting element.
Please install it by a recommended method.
The recommended installation position of the MD-SX sensors is upper place from clank shaft and side of
figure below.
Fig. 9 Recommended attachment position of the sensor unit
MD-SX sensor
mounting position
[Example. 2]
MD-SX sensor
mounting position
[Example. 4]
2-strokes engine
MD-SX sensor
mounting position
[Example. 1]
MD-SX sensor
mounting position
[Example. 3]
4-stroke in-line engine
4-stroke V-engine
MD-SX sensor
mounting position
[Example. 1]
MD-SX sensor
mounting position
[Example. 2]
MD-SX sensor
mounting position
[Example. 2]
MD-SX sensor
mounting position
[Example. 1]
Original content from www.daihatsu.cc
Issued to HORIZON TANKERS LIMITED S.A.